Extron electronic IPL T CR48 Specifications, Part Numbers, Accessories, Relay control interface

Models: IPL T CR48

1 66
Download 66 pages 29.57 Kb
Page 58
Image 58
Specifications, Part Numbers, Accessories

Specifications, Part Numbers, Accessories

Specifications

Ethernet control interface

Connectors

1 RJ-45 female connector

Data rate

10/100Base-T, half/full duplex with

 

autodetect

Protocols

ARP, DHCP, ICMP (ping), TCP/IP, UDP/

 

IP, Telnet, HTTP, SMTP

Default settings

Link speed and duplex level =

 

autodetected

 

IP address = 192.168.254.254

 

Subnet mask = 255.255.0.0

 

Gateway = 0.0.0.0

 

DHCP = off

Web server

Up to 200 simultaneous sessions

 

1.25 MB nonvolatile user memory

Program control

Extron’s Simple Instruction Set (SIS)

Global Viewer requirements

Microsoft® Internet Explorer ver. 6 or

 

higher

Relay control interface

Quantity/type

8 normally open relays

Relay control connectors

(2) 3.5 mm captive screw connectors, 8

 

pole

Relay control contact rating

24 V, 1 A

Contact closure control interface

Quantity/type

4 contact closure inputs

Contact input control connector..

(1) 3.5 mm captive screw connector, 5 pole

Contact closure (input only)

 

Input voltage range

0 to 5 VDC, clamped at +5.1 V

Input impedance

10k ohms

Threshold

1.6 VDC

Pin configurations

1, 2, 3, 4 = inputs 1, 2, 3, 4; 5 = GND

General

Power

Supplied by an included external power

 

supply

External power supply

100 VAC to 240 VAC, 50/60 Hz, external;

 

to 12 VDC, 1 A, regulated

Power input requirements

12 VDC, 0.5 A

A-2 IPL T CR48 • Specifications, Part Numbers, and Accessories
Page 58