Extron electronic IPL T PC1i Step Eleven Set monitored conditions, Software Setup, cont’d

Models: IPL T PC1 IPL T PC1i

1 27
Download 27 pages 50.4 Kb
Page 22
Image 22
Step Eleven: Set monitored conditions.

Software Setup, cont’d

Step Eleven: Set monitored conditions.

The Monitor tab is used to set up a response (action and/or e-mail) to a specified condition or event.

Actions vary by selected device and include options such as Enable/Disable PINs, Lockout Front Panel, and Time Delay.

Custom e-mails can be created and sent to specified e-mail addresses following specified conditions or events.

To add a monitored condition,

1.

Select the Monitor tab.

2.

Click the Add Monitor button.

The Monitored Conditions Wizard opens (see next page).

3. Enter a unique monitored condition name. The two check boxes next to the Enter a Monitored Condition Name field are automatically selected:

Enabled: When selected, indicates that monitoring is enabled.

Re-arm:When checked, means that the specified action occurs every time the condition(s) are met.

4. Click Next.

5.

Select a Subject Port (device).

6.

Select an Available Option (condition) to monitor.

7.

Edit the condition Name field (if desired).

8.

Set the desired Condition Test Parameters (if available).

 

For an example of test parameters, see the screen on the

 

next page.

9.

If the Apply Condition button is grayed-out, click on the

 

condition name in the Monitored Conditions pane.

10.

Click the Apply Condition button.

3-20 IPL T PC1 Interface • Software Setup