TP cable termination
Monitor connector — Connect a video monitor to this 15-pin HD connector for buffered, high resolution video loop through.

Installation and Operation, cont’d

C

D RS-232 connector — Connect a serial communications device to this 3.5 mm, 3-pole captive screw connector for bidirectional RS-232 communication. Wire the connector as shown in figure 2-4.

Connected RS-232

MTP

Device Pins

Pins

Receive

Tx

Transmit

Rx

Ground

Gnd

TP cable termination

NRJ-45 termination with CAT 5, CAT 5e, or CAT 6 cable must comply with the TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections.

RJ-45 termination with Skew-Free A/V UTP cable must comply with TIA/EIA T568A only.

Figure 2-5 shows the recommended termination of TP cables in accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards. You can use either standard with CAT 5, 5e, or 6 cable, but use the same standard on both ends of the cable.

Figure 2-4RS-232 connector wiring

NBy default, the RS-232 portion of the TP link is unidirectional only from the transmitter to the receiver. If there is only one receiver in a system, a jumper within the receiver allows the RS-232 communication to be bidirectional. Refer to the MTP 15HD RS Series manual.

E

Pre-Peak switch — The Pre-Peak switch alters the TP signal

 

output to correct for long cable runs. See the table on page 1-4

 

for suggested switch settings based on the transmitted video

 

format and transmission distance.

F Transmitter Output connector — Connect one end of a TP cable

Side Pins:

1 2 3 4 5 6 78

Insert

Twisted

Pair Wires

RJ-45

Connector

 

T568A

T568B

 

Pin

Wire color

Wire color

Signal

1

White-green

White-orange

Red+/V. sync+

 

 

 

 

2

Green

Orange

Red–/V. sync–

 

 

 

 

3

White-orange

White-green

Mono audio+

 

 

 

 

4

Blue

Blue

Green+

 

 

 

 

5

White-blue

White-blue

Green–

 

 

 

 

6

Orange

Green

Mono audio–

 

 

 

 

7

White-brown

White-brown

Blue+/H. sync+

 

 

 

 

8

Brown

Brown

Blue–/H. sync–

 

 

 

 

NOTE If you are using Enhanced Skew-Free™ A/V cable, use the TIA/EIA T568A standard only.

to this RJ-45 female connector on the transmitter.

CDo not connect this device to a computer data or telecommunications network.

Connect the free end of the same TP cable from the transmitter to the receiver’s Input RJ-45 female connector.

See “TP cable termination” on the next page to properly wire the RJ-45 connectors.

Figure 2-5 — TP cable termination

NEnhanced Skew-free A/V cable is not recommended for Ethernet/LAN applications. This cable is specially designed for compatibility with Extron’s Twisted Pair products that are wired using the TIA/EIA 568 A standard.

The green, brown, and blue pairs of this cable have virtually identical lengths and should be used to transmit the RGB signals.

The orange pair of this cable has a different length and should not be used to transmit the RGB signals.

2-6

MTP 4T 15HD RS • Installation and Operation

MTP 4T 15HD RS • Installation and Operation

2-7

Page 11
Image 11
Extron electronic MTP 4T 15HD RS TP cable termination, Installation and Operation, cont’d, 4- RS-232connector wiring