Extron electronic MVX 44, MVX 88, MVX 48, MVX 84 Resetting the system to factory defaults, Memory

Models: MVX 48 MVX 84 MVX 44 MVX 88

1 78
Download 78 pages 29.23 Kb
Page 41
Image 41

Resetting the system to factory defaults

To reset a switcher to the factory default settings, press and hold the I/O button on the front panel while applying AC power (figure 3-42). Continue to hold the I/O button until all LEDs light and then release the I/O button. The power up sequence completes (all LEDs turn off then turn on and off from left to right, the Video and Audio LEDs turn on, and all other LED remain off). System reset does the following:

Clears all ties and presets.

Clears all video and audio mutes.

Sets all input audio gain levels to their default (0 dB) values.

Returns the output audio level to the professional (+4 dBu) level.

Press and hold the I/O button while you apply power to the switcher.

I/O

VID

AUD

The switcher lights all of the LEDs.

1

1

Power

 

PRESET

I/O

 

VID

+dB

I / O

AUD

- dB

 

 

AUDIO SETUP

Release the I/O button.

I/O

VID

The switcher continues the power up process. AUD

Figure 3-42 — System reset to factory defaults

Memory

The current configuration, all presets, and all input audio levels are saved in non- volatile memory within 5 seconds of a change or exiting Audio Setup mode. When power is applied, the last current configuration is retrieved. The previous presets remain intact.

Wait at least 5 seconds after changing any configuration, saving a preset, or exiting Audio Setup mode. Before 5 seconds have elapsed, changes that you have made may not have been saved.

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Operation 3-25

Page 41
Image 41
Extron electronic MVX 44, MVX 88, MVX 48, MVX 84 manual Resetting the system to factory defaults, Memory