Front Panel Adjustments
Video signals passing through long cable runs (over 125 feet) can decrease in strength, creating signal loss. The longer the cable, the greater the cable resistance and capacitance, and the greater the level and peaking adjustments that will be required to compensate for the resultant signal loss. These adjustments change the level and peaking of the output signal to compensate for capacitance caused by up to 1000 feet (304.8 meters) of Extron SHR cable.
If the displayed image is too bright or too dark, try changing the level setting. If the edges of the displayed image seem to exceed their boundaries, or if thin lines and sharp edges look thick and fuzzy, try changing the peaking setting. See the illustration below.
|
|
|
| TPUT | xi |
|
|
| EOOU | 580 | |
|
| VID |
| RGB | |
INP G | L |
|
| Peaking | |
UTS | NTRO |
|
|
|
|
CO |
|
|
|
| |
ANALO |
|
|
|
|
|
AUDIO
Level
1.Level adjustment control — The Video Output Level control alters the brightness of the displayed image. To adjust the video output level, view the display while using a small,
If the interface receives a typical (0.7 volts
•At the minimum level setting (the counterclockwise limit of this control), the interface outputs video at
0.5volts
•Unity level is 0.7 volts
•At the maximum level setting (the clockwise limit of this control), the interface outputs video at
1.45volts
Select a level setting of 0.7 volts or above to compensate for the decrease in signal level that occurs when the signal
2-10 RGB 580xi • Installation and Setup
passes through long cables. Set the level at the maximum setting for cable lengths over 500 feet for all computer signals of 15 kHz to 135 kHz.
2.Peaking control — The Video Output Peaking control affects the sharpness of a picture. Increased peaking can compensate for detail (mid- and
Mounting the Optional AAP Device
Extron’s various RGB 580xi AAP
1.Insert the AAP’s screws through the holes in the AAP faceplate or the AAP wallplate. Secure the AAP device to the faceplate or wallplate with the provided captive washers and
Cable
Clamp
AAP 102
Cable
| P 10 | 2 |
AA |
|
|
COMP | UTER |
|
RGB 580xi SI AAP
#4-40 Nut w/ Captive Washer
Example of mounting an AAP device to a wallplate