Installation, cont’d

Inside

Outside

SVEQ 100 back of the rack installation example

Installing the CVEQ 100 AAP/SVEQ 100 AAP

The CVEQ 100 AAP and SVEQ 100 AAP are double space high architectural adapter plate products that mount in a wall or furniture using an optional mounting frame.

1. Remove power from the line driver by disconnecting the power supply.

2. Attach the mounting frame to wall box.

3. Route output cables through the wall box and frame and connect them to the line driver.

4. Mount the line driver to the mounting frame with machine screws, as shown in the following illustration. Take care not to damage the output cable(s), which fit through the mounting frame and into the wall box.

Cable

Clamp

 

AAP 102

 

Connector

 

102

 

AAP

 

AAP

 

100

 

CVEQ

#4-40 Nut w/ Captive

Extron

Washer

CVEQ 100 AAP

 

 

Composite Line Driver

Mounting the line driver to a wall box

5. Reconnect the power supply, cable all products (see chapter 3), and restore power to the equipment.

2-10 CVEQ 100 and SVEQ 100 Series • Installation

CVEQ 100 and SVEQ 100 Series • Installation 2-11