Extron electronic TPX 88 Command/response table for SIS commands Cont’d, Response, ASCII Command

Models: TPX 88 A TPX 88

1 82
Download 82 pages 58.99 Kb
Page 64
Image 64
Command/response table for SIS commands (Cont’d)

Programmer’s Guide, cont’d

Command/response table for SIS commands (Cont’d)

Command

ASCII Command

Response

Additional description

 

 

 

(host to switcher)

(switcher to host)

 

Audio input gain and attenuation

 

 

 

 

 

 

 

 

 

 

The set gain (G) and attenuation (g) commands are case sensitive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set audio input gain to +dB value

X1

*

X5

G

In

 

X1

•Aud

X4

 

 

Example:

1*2G

In01•Aud+02

Set input 1 audio level to +2 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gain.

Set audio input attenuation to -dB value

 

*

 

g

In

 

 

•Aud

 

 

 

X1

X6

 

X1

X4

 

Example:

3*5g

In03•Aud-05

Set input 3 audio level to -5 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

attenuation.

Increment gain

X1

+G

In

 

X1

•Aud

X4

 

Increase gain by 1 dB.

Example:

5+G

In05•Aud+03

Audio input 5 level incremented

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from +2 dB to +3 dB.

Decrement gain

 

-G

In

 

 

•Aud

 

 

Decrease gain by 1 dB.

X1

 

X1

X4

Example:

7-G

In07•Aud-09

Audio input 7 level decremented

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from -8 dB to -9 dB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read input gain

X1

G

 

X4

 

 

Example:

2G

+11

 

 

 

Input 2 audio level is +11 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gain.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Audio output volume

The adjustment range is between 0 and 100% audio output volume in 1 dB steps of attenuation. Each 1 dB equals approximately a 2% reduction in audio output volume.

Set audio volume to % of max. value

Example:

Odd-numbered

 

X3

*

X7

V

Out

X3

•Vol

X7

 

1*50v

Out01•Vol50

Set output 1 volume to 50%.

X7 values are rounded up to even-numbered values.

Increase volume

X3

+V

Out

X3

•Vol

X7

Increase volume by 2%.

Example:

1+V

Out01•Vol52

Audio output 1 level

 

 

 

 

 

 

 

incremented from 50% to 52%.

 

 

 

 

 

 

 

 

Decrease volume

X3

-V

Out

X3

•Vol

X7

Decrease volume by 2%.

Example:

1-V

Out01•Vol50

Audio output 1 level

 

 

 

 

 

 

 

incremented from 52% to 50%.

Read output volume

 

X3

Example:

V

V

X7

Vol50

Audio output 1 level is 50%.

Audio mute commands

Audio mute

X3

*1Z

Amt

X3

*1

Mute output

X3

audio (audio

 

 

 

 

 

 

 

off).

Example:

3*1Z

Amt03

Mute output 3 audio.

Audio unmute

 

*0Z

Amt

 

*0

Unmute output

 

audio (audio

X3

X3

X3

 

 

 

 

 

 

 

on).

 

 

 

 

 

 

 

 

 

 

 

 

Read audio mute

X3

Z

X8

 

1= mute on, 0 = mute off.

Global audio mute

1*Z

Amt1

Mute all audio outputs. The

 

 

 

 

 

 

 

front panel Mute All LED lights.

 

 

 

 

 

 

 

 

 

 

 

 

Global audio unmute

0*Z

Amt0

Unmute all audio outputs. The

 

 

 

 

 

 

 

front panel Mute All LED goes

 

 

 

 

 

 

 

out.

4-6 TPX 88 Matrix Switchers • Programmer’s Guide

Page 64
Image 64
Extron electronic Command/response table for SIS commands Cont’d, TPX 88 Matrix Switchers Programmer’s Guide, Response