The VN-Matrix Enterprise Controller IP address and port number are entered in the first two fields (see figure 12).

Figure 12. Controller IP Address and Port, Local IP Address and Port

Controller IP Address: The Controller IP Address is the IP address of the VNMatrix Enterprise Controller that the VNS 104 connects to.

Controller Port: The Controller Port number shown in figure 12 (5432) is used by all VNMatrix devices to communicate with the Enterprise controller. The value is only changed if the Enterprise Controller is configured to accept communications on a different port number. Under normal circumstances the setting should remain at the default setting (5432).

Local IP Address: The IP Address of the PC the VNS 104 is installed on. If the PC has more than one network interface (NIC), select the required IP address from the dropdown box.

Local Port: The Local Port is a read only value set by the VNS 104 application during installation.

Defaults: The Defaults button restores the Controller Port and Local Port values to their defaults (shown in figure 12 above).