{PW} 76 ff yyyy (zzzz)

IF-THEN-ELSE

 

 

 

‘ff’ is the feature to be tested

 

 

 

‘yyyy’ is the macro to be executed if the feature tests non-zero / true.

 

‘zzzz’ is the optional macro to be executed if the feature tests zero / false.

 

 

 

 

 

 

 

Function ‘ff’

 

Item Tested

Function ‘ff’

 

Item Tested

00

7KDAB installed

33

 

Rx1 Anti-Kerchunk Timer

01

User Input 1

34

 

Rx1 Anti-Kerchunk Rearm Timer

02

User Input 2

35

 

Rx1 Timeout Penalty Timer

03

User Input 3

36

 

Rx1 Activity Timer

04

User Input 4

37

 

Tx2 ID Timer

05

User Input 5

38

 

Tx2 Unkey Delay Timer

06

User Input 6

39

 

Rx2 Activity Timer

07

User Output 1

40

 

Rx3 Activity Timer

08

User Output 2

41

 

Autopatch Redial Timer

09

User Output 3

42

 

Autopatch Timeout Message Timer

10

User Output 4

43

 

Autopatch Call Duration Timer

11

User Output 5

44

 

Landline Control Timer

12

User Output 6

45

 

Landline Ringout Message Timer

13

User Output 7

46

 

Landline Timeout Warning Timer

14

Rx1 COR

47

 

Landline inter-ring timer

15

Rx1 CTCSS

48

 

User Timer 1

16

Rx2 COR

49

 

User Timer 2

17

Rx2 CTCSS

50

 

User Timer 3

18

Rx3 COR

51

 

User Timer 4

19

Rx3 CTCSS

52

 

User Timer 5

20

PTT 1

 

53

 

User Timer 6

21

PTT 2

 

54

 

User Timer 7

22

Land Line Busy Input

55

 

User Timer 8

23

Land Line Ring Input

56

 

User Timer 9

24

Land Line Busy Output

57

 

User Timer 10

25

Tx1 ID Timer

58

 

User Switch 1 (cmd 63 92 x)

26

Tx1 Post Activity Timer

59

 

User Switch 2 (cmd 63 93 x)

27

Tx1 Drop Out Timer

60

 

User Switch 3 (cmd 63 94 x)

28

Tx1 Courtesy Timer

61

 

User Switch 4 (cmd 63 95 x)

29

Tx1 Unkey Delay Timer

62

 

User Switch 5 (cmd 63 96 x)

30

Rx1->Tx1 Timeout Timer

63

 

User Switch 6 (cmd 63 97 x)

31

Rx2->Tx1 Timeout Timer

64

 

User Switch 7 (cmd 63 98 x)

32

Rx3->Tx1 Timeout Timer

 

 

 

Example:

{PW} 76 03 2001 2000 ;test user input 3, if input is active then execute macro 2001,

;otherwise execute macro 2000.

7KDAB, Version 2.0, 19-Aug-2007

© Vyex LLC, 2003-2007

49

Page 54
Image 54
FARGO electronic 7KDAB manual PW 76 ff yyyy zzzz, Function ‘ff’ Item Tested