{PW} 49 90/91/92/93 xx Message Handler Initial Message Delay

Timer’s 90 through 93 now allow the user to determine the initial message delay value for individual message types.

In previous versions, these timer delay values were fixed at 1.0 seconds. The user can now specify a timer value of zero to 5.0 seconds with 100ms resolution.

Timer:

90 – CW pre-message delay associated with special message character ‘54’ 91 – Beep pre-message delay associated with special message character ‘54’ 92 – Paging pre-message delay that is always present

93 – Speech pre-message delay associated with special word ‘0000’

These timer delay’s are utilized only at the beginning of a new message sequence, and with the exception of a paging sequence, the delay only occurs if the message begins with the special message character or word.

Examples:

 

{PW} 49 90 15

;set CW initial delay to 1.5 seconds

{PW} 49 93 20

;set speech initial delay to 2.0 seconds

;send CW message “KA9FUR” with an initial delay {PW} 15 9900 54 59 0852 67 20 10 09 15 30 27

;send speech message “KA9FUR repeater” with an initial delay {PW} 15 9960 0000 0260 0001 0335 0149 0540 0401 0421

{PW} 49 94/95 xx Logic output pulse duration

These timers were introduced in version 2.04f.

Timer 94 now sets the logic pulse ON duration, and timer 95 sets the logic pulse OFF duration. Timer units are in 10ms increments with the minimum value of 10ms and the maximum of 2540ms.

The pulsed output duration may vary up to +/-10ms.

NOTE: If new firmware is installed in a controller that previously contained an older 2.04 variant AND the controller is not cold initialized, the timer values will default to zero, meaning the pulsed outputs will not work. In order to retain backward compatibility either manually set both of the timer values to ‘50’ (500ms), OR cold initialize the controller.

Examples:

 

{PW} 49 94 50

;set logic output pulsed on delay to 500ms

{PW} 49 95 10

;set logic output pulsed off delay to 100ms

7KDAB, Version 2.0, 19-Aug-2007

© Vyex LLC, 2003-2007

48

Page 53
Image 53
FARGO electronic 7KDAB manual PW 49 90/91/92/93 xx Message Handler Initial Message Delay