Fedders Portable Dehumidifier Cleaning and Maintenance, Draining excess water

Models: Portable Dehumidifier

1 28
Download 28 pages 23.07 Kb
Page 8
Image 8
Maintenance

Maintenance

Cleaning and Maintenance

The unit has an air filter that must be cleaned with water every two weeks and put back in the unit after it is completely dry.

The air discharge grille can be cleaned with a rag or sponge, warm water and mild detergent.

Never use hot water, bleach, gasoline, acids, cleaning fluid or a brush to clean the unit. This will damage the cabinet and the air discharge area.

Do not wash the unit with a hose.

Cleaning the filter.

1.Turn Power OFF.

2.Remove the air filter by grasping the bottom and pulling it up and out of the unit.

3.Wash in hot soapy water, rinse and shake dry.

4.Replace the filter with the front of the filter toward you.

5.To dry the filter thoroughly, run your unit in fan mode for a few minutes. Remember, only a clean filter works properly and delivers top efficiency at every setting.

Warning: Make sure unit is unplugged before performing any maintenance procedure.

Draining excess water

Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning Light will shine and the unit will not operate until the unit has been drained.

First, uplug electrical cord from wall outlet. Then, drain excess water from the tank by placing a pan under the drain valve, removing the drain plug, and letting the water drain into the pan.

When the water stops draining out, replace the drain plug, and remove the pan of water. Operate the air conditioner in fan mode to dry the interior of the unit.

Always drain the unit before putting it into storage.

Air Conditioner Remote Control

The functions work the same as your air conditioner’s touch controls.

Batteries: Remove the cover on the back of the remote controller and insert the batteries with the (+) and (-) poles pointing in the proper direction.

10

Removing the filter

Proper use and care of

your air conditioner will

 

 

help ensure longer life of the unit. It is recommended to have a professional annually inspect and clean the coils and condensate water passages. Expense of annual inspection is the consumer’s responsibility.

CAUTION

Failure to keep air filter clean will result in poor air circulation. DO NOT operate without filter. This can render the unit inoperative.

11

Drain Valve

-

R03 IEC

5V.1 AAA

 

+

AAA 1.5V

IEC R03

CAUTION:

Use only AAA or IEC R03 1.5V batteries.

Do not attempt to recharge the supplied batteries

All batteries should be replaced at the same time.

Do not dispose of the batteries in a fire as they may explode.

Do not mix old and new batteries.

Do not install the batteries with the polarity (+/–) reversed.

Do not mix alkaline, standard (carbon - zinc), or rechargeable (nickel-cadmium) batteries.

Keep batteries and other things that could be swallowed away from young children. Contact a

doctor immediately if an object is swallowed.

8

Page 8
Image 8
Fedders Portable Dehumidifier Cleaning and Maintenance, Draining excess water, Air Conditioner Remote Control