GROUNDING AND HUMS

GROUNDING AND HUMS

 

TROUBLESHOOTING

 

 

 

Ground loops are one of the most common causes of hum and buzz in sound reinforcement systems and other

audio products. A ground loop usually occurs if the separate pieces of equipment are plugged into different AC

circuits. Also, if the audio wiring is placed too close to the power cords, hums or buzzes can bleed into the system. Still, improperly maintained power and audio cables are yet another cause of bothersome noise. In order to help minimize stray hums and buzzes, here are some helpful hints.

1.Keep all electronics connected to the sound system on the same electrical circuit.

2.Keep audio signal cables away from the AC power cords.

3.Use balanced cables when applicable.

4.Always plug the SRM 6302 / 8302 into a grounded AC electrical outlet.

5.Be sure to use properly maintained cords and cables with the SRM 6302 / 8302.

TOLEX COVERING CARE

The SRM 6302 / 8302 is covered in genuine Tolex® for long life and lasting good looks. To clean the cabinet, use a sponge with a light soapy solution. Avoid spilling any liquids on the operating

surface, heat sink, grille, volume and tone controls, switches and line cord. ALWAYS unplug the SRM 6302 / 8302 before cleaning it or approaching it with fluids. Before plugging in the SRM 6302 / 8302 wait until the unit has completely dried.

If the SRM 6302 / 8302 is set up but does not function, please check the following items:

Is the SRM 6302 / 8302's power cord properly plugged into an electrical outlet?

Is there power at the outlet?

(If applicable) does your instrument have power?

Are the volume control knobs on the SRM 6302 / 8302 turned above the 0 position?

Are the volume control knobs on your instruments turned above their minimum position?

Is the mic/instrument properly plugged into the SRM 6302 / 8302?

Is the mic/instrument turned on?

Are your audio cables frayed, cut or damaged?

If using a condenser mic, is the phantom power turned on?

If using an outboard gear, are the cords properly connected?

Is there power to the outboard gear?

Are the levels on your outboard gear above their minimum positions?

If after checking all of the above the SRM 6302 / 8302 is still not performing correctly, consult your authorized Fender Service Center.