Technical data

Symbols TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDER- STAND INSTRUCTION MANUAL.

responding cutters such as are listed in the Festool catalogues.

Functional description The user is liable for damages

and injuries due to incorrect usage.

Technical data

Power

12 A

Voltage

~ 120 V, 60 Hz

No load speed

10000 - 22500 rpm

Quick height adjustment

70 mm (2.76“)

Fine height adjustment

8 mm (0.31“)

Router diameter, max.

63 mm

Drive shaft connection of

the spindle

M 22x1

Weight

4.5 kg (9.9 lbs)

Protection class

/ II

 

Symbols

V

Volts

A

Amperes

Hz

Hertz

~

Alternating current

n0

No load speed

 

Class II Construction

rpm Revolutions or reciprocation per minute

ØDiameter

Functional description

The pictures for the functional description are on a fold-out page at the beginning of the instruction manual. When reading of the manual you can fold out this page for having always an overview of the machine.

1.1Speed controller

1.2Locking button

1.3On/Off switch

1.4Scale

1.5Spindle stop

1.6Pivoted turret stop

1.7Collet nut

Use for intended purpose

The routers are designed for routing wood, plastics and similar materials. Aluminium and plasterboard can also be processed with cor-

Electrical connection

The network voltage must conform to the voltage indicated on the rating plate. A 16 A safety fuse (for 120 V) or a corresponding protective circuit-breaker is required.

See the following figure for connection and disconnection of the power cable.

Use for intended purpose Always switch the machine off before connecting or disconnecting the power cable!

2

Extension cable

If an extension cable is required, it must have a sufficient cross-section so as to prevent an excessive drop in voltage or overheating. An excessive drop in voltage reduces the output and can lead to failure of the motor. The table below shows you the correct cable diameter as a function of the cable length for the router OF 1400 EQ. Use only U.L. and CSA listed exten- sion cables. Never use two extension cables together. Instead, use one long one.

Total Extension Cord

25

50

100

150

Lenght (feed)

 

 

 

 

Cord size (AWG)

16

14

12

10

 

 

 

 

 

Note: The lower the AWG number, the stron- ger the cable.

Switching the ma-

chine on and off

Electrical connection Keep the machine steady dur- ing switching and during use by holding the handles (3.1, 3.4) with both hands.

Switch (3.3) serves as an On/Off switch. It may be latched with the locking knob on the side (3.2) for continuous operation. Pressing the switch again releases the lock.

6

Page 6
Image 6
Festool OF 1400 EQ Technical data, Symbols, Functional description, Use for intended purpose, Electrical connection