2.Pre-Startup checklist

2.1.Accessories supplied with the SlotServer

Please verify that the following components were supplied with the SlotServer module:

FieldServer Technologies

 

Description

 

PART #

 

 

 

 

 

 

 

2-way combi-comb connector for LonWorks port

 

 

Software CD

 

 

CAT-5 Direct Ethernet Cable

 

 

Documentation Binder

2.2.Third party components (not supplied by FieldServer Technologies)

The following components will need to be procured as a minimum for achieving ControlLogix integration. Ensure that these are available before commencing with commissioning

Part #

Description

AB1756-Ax

ControlLogix Rack

AB1756-L55/L61

ControlLogix CPU

AB1756-PA7x

ControlLogix PSU

9324-RLD300ENE

RSLOGIX 5000

 

 

2.3.Required configuration for the SlotServer

To achieve data transfer between CPU tags and the SlotServer third party protocols, it will be necessary to write and load a configuration into the SlotServer that tells the SlotServer how to map the ControlLogix Tags to the required protocol addresses. This configuration is written in a Comma Separated Variable (csv) file, and any text editor or spreadsheet program that supports csv format can be used for this purpose. FieldServer Technologies provides an example configuration file so that the configuration does not need to be written from scratch. Configuration parameters needed to exchange data between the CPU and the SlotServer data images (Data Arrays) are presented in Section 6. The appropriate driver manual supplement will describe how to map the data in and out of the Data Arrays for the relevant protocol.

The FieldServer configuration manual details basic and advanced techniques for the configuration of the SlotServer Manual, and it is strongly advised that this manual is read before attempting to write the SlotServer Configuration.

Note: FieldServer Technologies provides SlotServer configuration services if the user does not wish to perform the configuration themselves.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Page 5
Image 5
FieldServer FS-RA-CLX-BAS instruction manual Required configuration for the SlotServer, Rslogix

FS-RA-CLX-BAS specifications

The FieldServer FS-RA-CLX-BAS is a robust communication gateway designed to facilitate interoperability between building automation systems and various network protocols. Its main objective is to provide seamless integration, allowing different systems to communicate effectively, regardless of their underlying technologies.

One of the standout features of the FS-RA-CLX-BAS is its support for a wide range of communication protocols. It can easily bridge between BACnet, Modbus, Johnson Controls N2, and several others, making it an invaluable tool in diverse environments where equipment from multiple manufacturers needs to work together. This extensive compatibility helps streamline operations, reduce costs, and enhance system efficiency.

The device is designed with a user-friendly interface that simplifies setup and configuration. It features a web-based management platform that allows system integrators and technicians to configure settings, monitor system performance, and perform troubleshooting tasks remotely. This accessibility is particularly beneficial in minimizing downtime and ensuring that systems operate optimally.

FieldServer Technologies has also implemented advanced data logging capabilities within the FS-RA-CLX-BAS. Users can track real-time data trends, monitor system performance, and analyze historical data to make informed decisions. This feature is essential for identifying inefficiencies and enabling proactive maintenance, thus extending the lifespan of building systems.

The FS-RA-CLX-BAS is built with durability and reliability in mind, designed for use in demanding environments. Its compact design and robust construction allow for easy integration into existing setups without requiring extensive modifications. Additionally, with support for both wired and wireless communication methods, it offers flexibility in installation.

Beyond its core functions, the FS-RA-CLX-BAS is also equipped with security features to protect sensitive data being transmitted across networks. Encryption protocols help ensure that communications remain secure, mitigating risks associated with unauthorized access.

In summary, the FieldServer FS-RA-CLX-BAS stands out as a versatile and reliable solution for integrating various building automation systems. With its multi-protocol support, user-friendly interface, advanced data logging capabilities, and robust security measures, it empowers facility managers and system integrators to enhance operational efficiency while maintaining a high level of security and reliability. This makes it a key asset for modern building management and automation strategies.