Connecting the cable

Installation instructions

5

Single phase connection:

The supply cable should be at least equivalent to an ordinary PVC sheathed and insulated min. 4 mm2, three-core (twin and earth), min. 1 m long flexible cable.

Two-phase connection:

The supply cable should be at least equivalent to an ordinary PVC sheathed and insulated, min. 2.5 mm2, four-core, min. 1 m long flexible cable. If fitted the bridging link between 2 and 3 should be removed, as shown. Failure to this will result in damage to the appliance.

Remove for two-phase connection

This appliance must be connected to a circuit which incorporates an isolating switch providing full disconnection from the power supply.

If you raised the cooker to align it with the bench, make sure the base of the cooker cannot slip.

Connecting the cable

1Remove the cable access cover (lower right hand corner).

2 Provide a minimum of 1 metre of cable.

For 220-240 single phase operation, connect phase wire to terminal 1 ( with links between 1-2 and between 2-3 fitted).

For 380-415V two phase operation, remove the link between 2-3 and connect phase 1 wire to terminal 1 (with link between 1-2 fitted); then connect phase 2 wire to terminal 3.

3Connect neutral wire to terminal 5 (with link between 4-5 fitted).

4 Connect ground wire to earth terminal Manual background .

5 Replace cover; check that no conductors are trapped by the wiring cover.

Note: clocks are suitable for 50Hz supply only.