16
Installation instructions
Ventilation requirements (GB & IE only)
The appliance should be installed into a room or space with an air supply in accordance with BS
For rooms with a volume of less than 5 m3 - permanent ventilation of 100 mm2 free area will be required.
For rooms with a volume of between 5 m3 and 10 m3 a permanent ventilation of 50 cm2 free area will be required unless the room has a door which opens directly to the outside air in which case no permanent ventilation is required.
For rooms with a volume greater than 10 m3 - no permanent ventilation is required.
Important!
Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS
Gas installation (GB & IE only)
Important!
This cooker uses NATURAL GAS only and cannot be used on any other gas without modification. This appliance is manufactured for conversion to LPG if required. If the injectors are not supplied they can be obtained from the
Installation and service regulations
Important!
This appliance must be installed and serviced only by a suitably qualified and registered person, and in accordance with the current editions of the following standards and regulations or other locally applicable regulations:
Gas Safety (Installation and Use) Regulations Building Regulations
British Standards
Regulations for Electrical Installation
Failure to install the appliance correctly could invalidate any manufacturer’s warranty and lead to prosecution under the
Gas connection
The installation of the cooker to Natural Gas or LP Gas must be carried out by a qualified gas engineer. Installers shall take due account of the provisions of the relevant British Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.
Note: It is recommended that the gas connection to the cooker is installed with a flexible connecting tube made to BS 5386.