Fisher & Paykel OR90L installation instructions Connecting the feeder cable, Power Supply

Models: OR90L

1 56
Download 56 pages 44.12 Kb
Page 23
Image 23

Installation instructions

21

Connecting the feeder cable

To connect the feeder cable to the cooker: Remove the screws securing the

cover “A” on the rear of the cooker. Feed the supply cable through the cable clamp “D”. See the ‘Feeder cable section’ following for the correct size for the cable.

Connect the wires to the terminal block “B” as shown in the diagram; or connect the phase wires to the terminal block “B” and the earth wire to the terminal PE as shown.

Take up any slack in the cable and secure with the cable clamp “D”. Replace the cover “A”.

N.B. The earth conductor must be left about 3 cm longer than the others.

PE

N

D

L

 

B

 

A

Figure 16a Connecting the feeder cable

Power Supply

230V - 50Hz 4500W 19,5A (230V)

Feeder cable section “TYPE H05RR-F”

230V

3 x 2.5 mm2 (**)

(**)- Connection with wall box connection.

PEPE

NL NL

230 V

L1 N PE (L2)

Earth

Earth

Neutral

Neutral

Live

Live

Figure 16b Connecting the feeder cable

Page 23
Image 23
Fisher & Paykel OR90L installation instructions Connecting the feeder cable, Power Supply