Table for the choice of the injectors

 

 

GB

IE

Cat: II 2H3+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNERS

 

 

NOMINAL

 

REDUCED

G 30 - 28-30 mbar

G 20 - 20 mbar

 

 

 

 

 

POWER

 

POWER

G 31 - 37 mbar

 

 

 

 

 

 

[KW]

 

[KW]

 

 

 

 

 

 

 

Ø INJECTOR

Ø INJECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1/100 mm]

[1/100 mm]

 

AUXILIARY

 

 

1,00

 

0,30

50

72 (X)

 

SEMIRAPID

 

 

1,75

 

0,45

65

97 (Z)

 

 

RAPID

 

 

3,00

 

0,75

85

115 (Y)

TRIPLE-RING WOK

 

3,50

 

1,50

95

135 (T)

Lubrication of the gas taps

A qualified technician must lubricate the gas taps.

Important!

All intervention regarding installation maintenance and conversion of the appliance must be fulfiled with original factory parts.

The manufacturer declines any liability if these correct parts are not used.