To run Traffic Generator in Ping mode, do the following:

1.Connect the Network Assistant to your network.

2.Press (Connectivity Tests) from the top-level

display (for xDSL, press xDSL Test then press the Traffic Generator tab and go to step 5).

3.Press (ITO).

4.Press the (Traffic Generator) tab.

5.Press or to configure Frames/second to the desired amount.

6.Press or to configure Frame Length as 60, 64, 128, 256, 512, 768, 1024, 1280, 1518, or 1520 bytes.

Note

The illegal sized frames of 60 and 1520 bytes most likely will not be responded to by remote devices.

7.Select PING as the frame type.

8.Configure the Target IP Address box by pressing the box and then entering the address from the displayed keypad.

9.Press (Start Traffic) to run Traffic Generator. Traffic is transmitted to the specified Target IP Address (station or network).

10.Press (Stop Traffic) to stop Traffic Generator.

Traffic is transmitted to the specified Target IP Address (station or network).

Ping Mode Results

Traffic Generator displays Ping mode results as it is running. You can adjust Frames/second and Frame Length while Traffic Generator is running to see the effect of traffic loading on your network or on a station.

Two meters show the Ping mode results. One meter shows the overall network traffic (in frames per second) and the other meter shows the rate of Echo Response packets received from the target device. Figure 7-8 shows Ping mode sample results.