Fluke Series II 7-16, OneTouch Series, Users Manual, 9. Traffic Generator Setup Display

Models: Series II

1 127
Download 127 pages 19.34 Kb
Page 99
Image 99

OneTouch Series II

Users Manual

1

2

3

4

5

6

ce707f.eps

Figure 7-9. Traffic Generator Setup Display

1.Rate indicates the current Traffic Generator bit rate excluding the Ethernet overhead of preamble and inter-frame gap.

2.Use the arrow icons to set the number of frames transmitted per second.

3.Use the arrow icons to set the frame length.

4.Select the Frame Type as MAC (Media Access Control), IP, or PING. Refer to the following sections on Traffic Generator modes for more information.

5.Select Broadcast (only available for a Frame Type of MAC) to transmit traffic as broadcast or do not select it to transmit traffic as unicast.

If you selected a Frame Type of IP or PING, the Broadcast selection changes to Target IP Address allowing you to specify an IP address by pressing the box and then entering the address from the displayed keypad.

6.Press (Start Traffic) to start generating traffic.

Press (Stop Traffic) to stop the Traffic Generator.