ITO – Internetwork Throughput Option

Introduction 7

1. Remote IP

Address

Enter the source IP address of the Network Assistant at the remote end by pressing the Remote IP Address box. For xDSL, enter the Target IP ATU-C Address. Enter the address with the keypad then press .

5.Select from the following upstream (to remote unit or central office for xDSL)

Speed

and downstream (from remote unit)

 

 

speeds to be tested:

 

ITOqSpeed Parameters

2.

IP Config

3.

Duration

4.

Data PRBS

Enables you to enter the IP address for the local (this) unit. Select the method for configuring the IP Address (Manual or DHCP). See Chapters 2 and 6 for more information.

Select 2, 10, 30, 60, 120 or 300 seconds, 1 hr, 12 hrs, or 18hrs as the duration of the test.

Select to send all zeros (All 0s), all ones (All 1s), alternating ones and zeros (Alt 1/0), or a Pseudo-Random Bit Sequence (PRBS). The PRBS pattern simulates normal data traffic.

ISDN 128 Kbps, T1 1.544 Mbps,

E1 2.048 Mbps, and 1 Mbps/1

Mbps

XDSL Speed Parameters

ANSI Asymmetrical Rates: 64

Kbps/1.5 Mbps, 160 Kbps/3 Mbps,

384 Kbps/4.6 Mbps,

640 Kbps/6 Mbps, 1 Mbps/1

qMbps.

Auto: Tests a range of speeds to determine the operating speed of RADSL modems. The following additional icons are displayed:

Start at

Select the lowest speed for the range of downstream rates to be tested.