ENGLISH

INSTALLER INSTRUCTIONS

Gas

 

Burner

Rated

Rated con-

Injector

Min

 

 

 

capacity

sumption

 

rated capacity

type

Series

No.

Ref.

 

(KW)

(l/h)

(ø mm)

(KW)

 

 

 

 

 

 

 

 

 

 

 

2

Auxiliary

1,00

95

0,72

0,52

 

 

 

 

 

 

 

 

 

 

3

Semi-quick

1,75

167

0,97

0,52

 

II

4

Quick

2,70

257

1,08

0,90

 

 

5

Triple crown

3,50

333

1,35

1,80

GASMETHANE mbar20G20

 

10

Dual

4,50

429

i 0.72 / and 1.02

i 0.46 / and 0.66

 

 

 

 

 

 

 

 

 

6

Auxiliary

1,10

105

0,73

0,52

 

III

7

Semi-quick

1,75

167

0,98

0,52

 

8

Quick

3,00

285

1,26

0,90

 

 

 

 

 

 

 

 

 

 

 

 

9

Triple crown

3,80

362

1,35

1,80

 

 

11

Auxiliary

1,00

95

0,72

0,52

 

 

 

 

 

 

 

 

 

AE

12

Semi-quick

1,75

167

0,97

0,52

 

13

Quick

3,00

285

1,32

0,90

 

 

 

 

 

 

 

 

 

 

 

 

14

Dual gear

5,00

476

i 0.75 / and 1.58

i 0.30 / and 1.40

The appliance is tested for methane gas G20 (2H) at a pressure of 20 mbar. When using with other types of gas it is necessary to replace the burner nozzles, and adjust the minimum flame on the gas taps. For nozzle replacement, proceed as described in the following paragraphs.

11.1 Cooker hob nozzle replacement

IMPORTANT: Before completing the following operations, always make sure that the appliance is disconnected from the power mains.

1.Remove the grids, remove all flame spreading caps and crowns.

2.Using a 7 mm tube spanner, unscrew the burner nozzles [Fig.7].

3.Proceed with burner nozzle replacement based on the type of gas to be used (table “Adapting to

different types of gasses [Page 31]).

4. Correctly reposition the burner in its seat.

Fig. 7: nozzle replacement

32

Page 14
Image 14
Foster 9606801 Cooker hob nozzle replacement, Different types of gasses, Correctly reposition the burner in its seat