ENGLISH
INSTALLER INSTRUCTIONS
Gas |
| Burner | Rated | Rated con- | Injector | Min | ||
|
|
| capacity | sumption |
| rated capacity | ||
type | Series | No. | Ref. |
| ||||
(KW) | (l/h) | (ø mm) | (KW) | |||||
| ||||||||
|
|
|
|
|
|
|
| |
|
| 2 | Auxiliary | 1,00 | 95 | 0,72 | 0,52 | |
|
|
|
|
|
|
|
| |
|
| 3 | 1,75 | 167 | 0,97 | 0,52 | ||
| II | 4 | Quick | 2,70 | 257 | 1,08 | 0,90 | |
|
| 5 | Triple crown | 3,50 | 333 | 1,35 | 1,80 | |
GASMETHANE mbar20G20 |
| 10 | Dual | 4,50 | 429 | i 0.72 / and 1.02 | i 0.46 / and 0.66 | |
|
|
|
|
|
|
| ||
|
| 6 | Auxiliary | 1,10 | 105 | 0,73 | 0,52 | |
| III | 7 | 1,75 | 167 | 0,98 | 0,52 | ||
| 8 | Quick | 3,00 | 285 | 1,26 | 0,90 | ||
|
| |||||||
|
|
|
|
|
|
|
| |
|
| 9 | Triple crown | 3,80 | 362 | 1,35 | 1,80 | |
|
| 11 | Auxiliary | 1,00 | 95 | 0,72 | 0,52 | |
|
|
|
|
|
|
|
| |
| AE | 12 | 1,75 | 167 | 0,97 | 0,52 | ||
| 13 | Quick | 3,00 | 285 | 1,32 | 0,90 | ||
|
| |||||||
|
|
|
|
|
|
|
| |
|
| 14 | Dual gear | 5,00 | 476 | i 0.75 / and 1.58 | i 0.30 / and 1.40 |
The appliance is tested for methane gas G20 (2H) at a pressure of 20 mbar. When using with other types of gas it is necessary to replace the burner nozzles, and adjust the minimum flame on the gas taps. For nozzle replacement, proceed as described in the following paragraphs.
11.1 Cooker hob nozzle replacement
IMPORTANT: Before completing the following operations, always make sure that the appliance is disconnected from the power mains.
1.Remove the grids, remove all flame spreading caps and crowns.
2.Using a 7 mm tube spanner, unscrew the burner nozzles [Fig.7].
3.Proceed with burner nozzle replacement based on the type of gas to be used (table “Adapting to
different types of gasses” [Page 31]).
4. Correctly reposition the burner in its seat.
Fig. 7: nozzle replacement
32