INSTALLER INSTRUCTIONS

IMPORTANT: After adjusting for use with a gas that is different from the initial testing one, replace the label on appliance housing with the one that corresponds to the new gas type.

ENGLISH

12. Adjustment of the minimum

Instructions for urban and methane gas

1. Light the burner and bring it to the minimum position.

2. Remove the gas tap knob and turn the adjust- ment screw [Fig. 8] inside or on the side of the tap rod (depending on the model), until a regular minimum flame is obtained.

3. Re-assemble the knob and verify burner flame

Fig. 8: adjustment of the minimum

stability (when quickly rotating the hand from

 

maximum to minimum position the flame must

 

not shut off).

 

4. Repeat the operation on all gas taps.

Instructions for liquid gas (LPG)

Tighten the screw inside, or on the side of the tap (depending on the mode), rod clockwise completely.

13. Electrical connection of the cooker hob

IMPORTANT: Before completing the following operation, always make sure that the voltage and sizing of the power supply line correspond to the characteristics indicated on the place located under the housing of the appliance. This plate must never be removed.

33

Page 15
Image 15
Foster 9606801 Adjustment of the minimum, Electrical connection of the cooker hob, Instructions for urban and methane gas