Table 9 Troubleshooting the Receiver

Problem

Possible Cause

 

 

1. Lack of RF signal

If a spectrum analyzer or power meter

 

present at Receiver,

is not available then use a DVM and

 

yet optical power is

adjust the gain control for RF signal

 

functioning.

strength (RSSI) so that the reading is

 

 

> 0.2VDC. (See Table 5 7870R Receiver

 

 

Pinout on page 21).

 

 

Conclusion: If signal still not present

 

 

then transmitter input stage amplifier

 

 

or receiver amplifier is defective.

 

 

Contact factory.

2.

No optical power,

a.

Transmitter is not functioning, see

 

LED not

b.

above.

 

illuminated.

There is a break or severe bend in

 

 

 

the fiber optic cable. Use an optical

 

 

 

power meter or another

 

 

 

functioning receiver unit to verify

 

 

 

optical power coming down the

 

 

c.

fiber.

 

 

The connector is dirty. Clean it.

 

 

d.

Optical power too low, too many

 

 

 

splits, too long a distance (thus

 

 

 

exceeding optical budget). System

 

 

 

may still function without LED

 

 

 

illuminated although at reduced

 

 

 

performance.

3.

Optical power light

Damaged (leaky) photodiode. Unit

 

illuminated with

may still function, otherwise contact

 

disconnected optical

Factory for service.

 

input.

 

 

4. The RF LED is not

Verify that the RF signal strength

 

illuminated.

(RSSI) is <0.2° VDC.

page 26

Document no. 93-005-35-C5

Page 34
Image 34
Foxconn 7870 manual May still function without LED