SYSTEM CONTROL SWITCH - TEST

Disconnect leads from control switch (See Figure 25) There must be continuity as follows:

Figure 25

SYSTEM CONTROL SWITCH (See Figure 26)

(Heat Pump & Electric Heat Models)

An eight position control switch is used to regulate the operation of the fan motor and compressor. The compressor can be operated with the fan operating at low, medium or high speed in the cooling or heating mode. The fan motor can also be operated independently on medium speed. See switch section as indicated on decorative control panel.

1."Off" Position - everything is off.

2."Lo Cool" Position - fan operates on low speed, compressor is on.

3."Med Cool" Position - fan operates on medium speed, compressor is on.

4."Hi Cool" Position - fan operates on high speed, compressor is on.

5."Hi Heat" Position - fan operates on high speed, compressor or electric heater is on.

6."Med Heat" Position - fan operates on medium speed, compressor or electric heater is on.

Figure 26

System Control Switch

SYSTEM CONTROL SWITCH

(Heat Pump & Electric Heat Models) (See Figure 27)

An eight position control switch is used to regulate the operation of the fan motor and compressor. The compressor can be operated with the fan operating at low, medium or high speed in the cooling or heating mode. The fan motor can also be operated independently on medium speed. See switch section as indicated on decorative control panel.

1."Off" Position - everything is off.

2."Lo Cool" Position - fan operates on low speed, compressor is on.

3."Med Cool" Position - fan operates on medium speed, compressor is on.

4."Hi Cool" Position - fan operates on high speed, compressor is on.

5."Hi Heat" Position - fan operates on high speed, compressor or electric heater is on.

6."Med Heat" Position - fan operates on medium speed, compressor or electric heater is on.

7."Lo Heat" Position - fan operates on low speed, compressor or electric heater is on.

8."Fan Only" Position - operates on medium speed.

NOTE: Heat pump models with electric heat - in the heat position, heating element only will be energized when outdoor temperature is below the operating range of the heat pump.

Figure 27

System Control Panel

Heat Pump & Electric Heat Models

(YS, ES, YM, EM, YL & EL)

21

Page 21
Image 21
Friedrich 2003 service manual System Control Switch, Heat Pump & Electric Heat Models See Figure