WS PERFORMANCE DATA

PERFORMANCE

EVAPORATOR AIR

OPERATING

ELECTRICAL

R-22

BREAKER

DATA*

TEMP. DEG. F.

PRESSURES

RATINGS

REFRIG.

FUSE

Cooling

 

 

 

 

 

 

 

 

Discharge

Temp.

Suction

Discharge

Amps

Locked

Charge in

60 Hertz

 

Air

Drop F.

 

 

 

Rotar Amp

OZ.

Amps

 

 

 

 

 

 

 

 

 

WS07A10E-B

59.5

19.5

84

300

7.'0

32

19

15

WS07A10E-C

59.5

19.5

85

299

7.'0

32

28

15

WS07A10E-D

59.5

19.5

85

299

7.'0

32

20

15

WS10A10-A

58

22

83

307

9.8

48

25

15

WS10A10-B

58

22

83

307

9.8

48

26

15

WS12A10E-B

55

25

81

290

11.9

54

28.5

15

WS13A10-A

55

25

79

281

12

55

36

15

WS09A30E-B

58

22

86

302

4.7

44

22

15

WS12A30E-A

47.1

32.9

80

308

11.9

54

27.5

15

WS12A30E-B

46

33

80

305

11.9

54

42

15

WS15A30-A

47

33

72

310

8.5

42

43.5

15

 

 

 

 

 

 

 

 

 

 

 

WE-WY PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

DATA*

EVAPORATOR

OPERATION

ELECTRICAL

R-22

BREAKER

Cooling

TEMP. DEG. F.

PRESSURES

RATINGS

REFRIG.

FUSE

 

Discharge

Temp.

Suction

Discharge

Amps

Locked

Charge in

60 Hertz

 

Air

Drop F.

 

 

 

Rotar Amp

OZ.

Amps

WE09A33E-C

58

22

86

302

4.7

44

23

20

WE12A33E-B

55

25

80

308

6.5

54

27.5

20

WE15A33-A

47.1

32.9

71

310

8.5

42

43.5

20

WY09A33F-A

58

22

83

288

4.3

44

24

20

WY12A33G-A

55

25

81

295

6.2

54

37

20

 

 

 

 

 

 

 

 

 

PERFORMANCE

Heat Rise

 

 

 

 

 

 

 

DATA heating

 

 

 

 

 

 

 

 

WE15A33-A

40

 

 

 

16.2

 

 

 

WE09A33E-C

39

 

 

 

14.7

 

 

 

WE12A33E-B

36

 

 

 

14.7

 

 

 

 

 

 

 

 

 

 

 

 

*Rating Conditions: 80 degree F. Room Air Temperature and 50% Relative Humidity 95 degree F. Outside Air Temperature at 40% Relative Humidity