PROBLEM

POSSIBLE CAUSE

TO CORRECT

 

 

 

 

Evaporator drain pan cracked or

Repair, clean or replace as required.

Outside water leaks.

obstructed.

 

Water in compressor area.

Detach shroud from pan and coil. Clean and

 

 

remove old sealer. Reseal, reinstall and check.

 

Obstructed condenser coil.

Steam clean.

 

Fan blade and slinger ring improperly

Adjust fan blade to 1/2" clearance from condenser

 

positioned.

coil.

PROBLEM

POSSIBLE CAUSE

TO CORRECT

 

 

 

 

 

Insufficient air circulation in air condi-

Adjust louvers for best possible air circulation

High indoor

tioned area.

 

 

Oversized unit.

Operate in "Fan-Auto (MoneySaver)" position.

humidity.

 

 

 

 

 

 

 

Inadequate vapor barrier in building

Advise customer.

 

 

structure, particularly floors.

 

 