Friedrich 2009, 2008 service manual Refrigerant System Diagnosis - Heating Cycle, Heat Pump

Models: 2009 2008

1 68
Download 68 pages 41.17 Kb
Page 49
Image 49
REFRIGERANT SYSTEM DIAGNOSIS - HEATING CYCLE

TROUBLESHOOTING CHART — HEATPUMP

REFRIGERANT SYSTEM DIAGNOSIS - HEATING CYCLE

LOW SUCTION PRESSURE ELECTRICAL TROUBLESHOOTING CHART — HEAT PUMPHEAT PUMPHIGH SUCTION PRESSURE

 

 

 

 

 

Low Airflow

 

Outdoor Ambient Too High

Across Outdoor Coil

 

for Operation in Heating

 

 

 

 

 

 

 

 

 

 

Refrigerant System

 

Reversing Valve not

Restriction

 

Fully Seated

 

 

 

 

 

 

 

 

 

 

Undercharged

 

Overcharged

 

 

 

 

 

 

 

 

 

 

Moisture in System

 

Defective Compressor

 

 

 

 

 

LOW HEAD PRESSURE

Refrigerant System

Restriction

Reversing Valve not Fully Seated

Undercharged

Defective Compressor

HIGH HEAD PRESSURE

Outdoor Ambient Too High For Operation In Heating

Low Airflow Across

Indoor Coil

Overcharged

Noncondensables (air)

in System

ELECTRICAL TROUBLESHOOTING CHART — HEAT PUMP

HEAT PUMP

SYSTEM COOLS WHEN

HEATING IS DESIRED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is Line Voltage

 

 

 

Is the Selector Switch

Present at the Solenoid

NO

 

Set for Heat?

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the Solenoid Coil Good?

 

 

 

Replace the Solenoid Coil

NO

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reversing Valve Stuck

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the Reversing Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

47

Page 49
Image 49
Friedrich 2009, 2008 Refrigerant System Diagnosis - Heating Cycle, Electrical Troubleshooting Chart - Heat Pump