Friedrich Chassis Specifications for 2009, 2008 models, Eer Cop, Model, Ratio Performance

Models: 2009 2008

1 68
Download 68 pages 41.17 Kb
Page 9
Image 9
Chassis Specifications for 2009, 2008 models

Chassis Specifications for 2009, 2008 models

Electrical Characteristics (60 Hertz) ENERGY STAR® Models

 

Cooling

Heating

Electrical Characteristics (60 Hertz)

 

 

 

 

 

 

 

Capacity

Capacity

Volts

Cooling

Cooling

Heating

Heating

Model

BTU/h

Rated

Rated

Amps

Watts

Amps

Watts

Energy Coefficient

Efficiency Of

Ratio Performance

EER COP

Moisture

Room Side

Weight

Removal

Air Circulation

Lbs.

Pints/Hr.

CFM

Sleeve* Ship/Net

ULTRA PREMIUM LINE

QUIETMASTER Programmable

SS08L10

 

8400

115

6.6

737

11.4

 

1.6

265

S

114/108

SS10L10

 

10400

115

7.5

867

12.0

 

2.5

260

S

121/115

SS12L10

 

11800

115

9.0

1000

11.8

 

2.5

350

S

120/114

SS14L10

 

14000

115

12.0

1305

10.7

 

3.5

377

S

134/128

SS12L30

 

12100/11900

230/208

4.8/5.0

1052/1017

11.5/11.7

 

2.9

320

S

120/114

SS16L30

 

16200/15900

230/208

7.4/8.0

1653/1656

9.8/9.6

 

4.7

360

S

125/119

SM18L30A

 

17500/17300

230/208

7.2/7.7

1620/1570

10.8/10.8

 

4.5

375

M

169/163

SM21L30

 

20600/20200

230/208

9.4/10.1

2081/2020

9.9/10.0

 

6.0

425

M

160/154

SM24L30

 

23500/23000

230/208

11.2/12.1

2479/2421

9.5/9.5

 

7.0

400

M

160/154

XSTAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XQ05L10A

 

5500

115

5.0

500

11.0

 

1.2

200

Q

76/70

XQ06L10A

 

6300

115

4.9

548

11.5

 

1.4

175

Q

76/70

XQ08L10A

 

8000

115

6.8

741

10.8

 

1.9

175

Q

83/77

XQ10L10A

 

10000

115

9.0

1000

10.0

 

3.2

180

Q

89/83

XQ12L10A

 

11700

115

11.0

1198

9.8

 

3.2

200

Q

89/83

PREMIUM LINE

 

 

 

 

 

 

 

 

 

 

 

 

QUIETMASTER

 

 

 

 

 

 

 

 

 

 

 

 

 

KS12L10

 

11600

115

9.0

1055

11.0

 

2.5

356

S

120/114

KS15L10

 

14500

115

12.0

1343

10.8

 

3.5

377

S

134/128

KM18L30

 

17800/17600

230/208

8.1/8.8

1780/1760

10.0/10.0

 

4.4

400

M

167/161

KM24L30

 

23500/23000

230/208

11.2/12.1

2479/2421

9.5/9.5

 

7.0

400

M

160/154

SL28L30

 

28000/27700

230/208

13.0/14.2

2947/2916

9.5/9.5

 

8.8

600

L

207/201

SL36L30A

 

36000/35700

230/208

18.0/19.6

4235/4200

8.5/8.5

 

11.0

725

L

226/220

TWINTEMP Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

YS09L10**

 

9200

7400

115

7.4

767

6.9

733

12.0

3.0

1.7

300

S

117/113

YS13L33

 

12700/12500

11000/10500

230/208

5.1/5.6

1149/1131

5.3/5.8

1185/1167

11.0/11.0

2.5/2.6

3.5

325

S

121/117

YM18L34

 

18000/18000

16800/16400

230/208

8.5/9.5

1895/1895

8.5/9.0

1867/1822

9.5/9.5

2.8/2.9

4.7

400

M

170/166

YL24L35

 

24000/24000

22000/21600

230/208

10.9/12.0

2400/2400

11.0/12.0

2444/2400

10.0/10.0

2.7/2.8

7.0

600

L

202/198

TWINTEMP Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

EQ08L11A

 

7700

4000

115

6.5

733

11.2

1290

10.5

 

1.9

175

Q

80/76

ES12L33

 

12100/11900

10700/8900

230/208

4.8/5.0

1052/1017

16.0/14.7

3500/2900

11.5/11.7

 

2.9

320

S

115/111

ES16L33

 

16200/15900

10700/8900

230/208

7.4/8.0

1653/1656

16.0/14.7

3500/2900

9.8/9.6

 

4.7

360

S

120/116

EM18L34

 

17800/17600

13000/10600

230/208

8.1/8.8

1780/1760

19.5/17.0

4200/3500

10.0/10.0

 

4.4

400

M

164/160

EM24L34

 

23500/23000

13000/10600

230/208

11.2/12.1

2479/2421

19.5/17.0

4200/3500

9.5/9.5

 

7.0

400

M

160/154

EL36L35A

 

36000/35700

17300/14300

230/208

18.0/19.6

4235/4200

24.0/22.4

5500/4650

8.5/8.5

 

11.0

725

L

224/220

*Sleeve dimensions listed on opposite page.

**Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 50° F to 115° F.

TwinTemp Heat Pump heating information (shown in red) indicates heat pump heating performance. TwinTemp Electric Heat heating information (shown in red) indicates electric heat strip performance. For TwinTemp Heat Pump electric heating performance refer to corresponding TwinTemp Electric Heat model.

Due to continuing research in new energy-saving technology, specifications are subject to change without notice.

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® (Model) models meet the ENERGY STAR® guidelines for energy efficiency.

The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.

7