![Chassis Specifications for 2009, 2008 models](/images/new-backgrounds/33236/3323617x1.webp)
Chassis Specifications for 2009, 2008 models
ENERGY STAR® Models
| Cooling | Heating | Electrical Characteristics (60 Hertz) | ||||
|
|
|
|
|
| ||
| Capacity | Capacity | Volts | Cooling | Cooling | Heating | Heating |
Model | BTU/h | Rated | Rated | Amps | Watts | Amps | Watts |
Energy Coefficient
Efficiency Of
Ratio Performance
EER COP
Moisture | Room Side | Weight |
Removal | Air Circulation | Lbs. |
Pints/Hr. | CFM | Sleeve* Ship/Net |
ULTRA PREMIUM LINE
QUIETMASTER Programmable
SS08L10 |
| 8400 | — | 115 | 6.6 | 737 | — | — | 11.4 |
| 1.6 | 265 | S | 114/108 |
SS10L10 |
| 10400 | — | 115 | 7.5 | 867 | — | — | 12.0 |
| 2.5 | 260 | S | 121/115 |
SS12L10 |
| 11800 | — | 115 | 9.0 | 1000 | — | — | 11.8 |
| 2.5 | 350 | S | 120/114 |
SS14L10 |
| 14000 | — | 115 | 12.0 | 1305 | — | — | 10.7 |
| 3.5 | 377 | S | 134/128 |
SS12L30 |
| 12100/11900 | — | 230/208 | 4.8/5.0 | 1052/1017 | — | — | 11.5/11.7 |
| 2.9 | 320 | S | 120/114 |
SS16L30 |
| 16200/15900 | — | 230/208 | 7.4/8.0 | 1653/1656 | — | — | 9.8/9.6 |
| 4.7 | 360 | S | 125/119 |
SM18L30A |
| 17500/17300 | — | 230/208 | 7.2/7.7 | 1620/1570 | — | — | 10.8/10.8 |
| 4.5 | 375 | M | 169/163 |
SM21L30 |
| 20600/20200 | — | 230/208 | 9.4/10.1 | 2081/2020 | — | — | 9.9/10.0 |
| 6.0 | 425 | M | 160/154 |
SM24L30 |
| 23500/23000 | — | 230/208 | 11.2/12.1 | 2479/2421 | — | — | 9.5/9.5 |
| 7.0 | 400 | M | 160/154 |
XSTAR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
XQ05L10A |
| 5500 | — | 115 | 5.0 | 500 | — | — | 11.0 |
| 1.2 | 200 | Q | 76/70 |
XQ06L10A |
| 6300 | — | 115 | 4.9 | 548 | — | — | 11.5 |
| 1.4 | 175 | Q | 76/70 |
XQ08L10A |
| 8000 | — | 115 | 6.8 | 741 | — | — | 10.8 |
| 1.9 | 175 | Q | 83/77 |
XQ10L10A |
| 10000 | — | 115 | 9.0 | 1000 | — | — | 10.0 |
| 3.2 | 180 | Q | 89/83 |
XQ12L10A |
| 11700 | — | 115 | 11.0 | 1198 | — | — | 9.8 |
| 3.2 | 200 | Q | 89/83 |
PREMIUM LINE |
|
|
|
|
|
|
|
|
|
|
|
| ||
QUIETMASTER |
|
|
|
|
|
|
|
|
|
|
|
|
| |
KS12L10 |
| 11600 | — | 115 | 9.0 | 1055 | — | — | 11.0 |
| 2.5 | 356 | S | 120/114 |
KS15L10 |
| 14500 | — | 115 | 12.0 | 1343 | — | — | 10.8 |
| 3.5 | 377 | S | 134/128 |
KM18L30 |
| 17800/17600 | — | 230/208 | 8.1/8.8 | 1780/1760 | — | — | 10.0/10.0 |
| 4.4 | 400 | M | 167/161 |
KM24L30 |
| 23500/23000 | — | 230/208 | 11.2/12.1 | 2479/2421 | — | — | 9.5/9.5 |
| 7.0 | 400 | M | 160/154 |
SL28L30 |
| 28000/27700 | — | 230/208 | 13.0/14.2 | 2947/2916 | — | — | 9.5/9.5 |
| 8.8 | 600 | L | 207/201 |
SL36L30A |
| 36000/35700 | — | 230/208 | 18.0/19.6 | 4235/4200 | — | — | 8.5/8.5 |
| 11.0 | 725 | L | 226/220 |
TWINTEMP Heat Pump |
|
|
|
|
|
|
|
|
|
|
|
| ||
YS09L10** |
| 9200 | 7400 | 115 | 7.4 | 767 | 6.9 | 733 | 12.0 | 3.0 | 1.7 | 300 | S | 117/113 |
YS13L33 |
| 12700/12500 | 11000/10500 | 230/208 | 5.1/5.6 | 1149/1131 | 5.3/5.8 | 1185/1167 | 11.0/11.0 | 2.5/2.6 | 3.5 | 325 | S | 121/117 |
YM18L34 |
| 18000/18000 | 16800/16400 | 230/208 | 8.5/9.5 | 1895/1895 | 8.5/9.0 | 1867/1822 | 9.5/9.5 | 2.8/2.9 | 4.7 | 400 | M | 170/166 |
YL24L35 |
| 24000/24000 | 22000/21600 | 230/208 | 10.9/12.0 | 2400/2400 | 11.0/12.0 | 2444/2400 | 10.0/10.0 | 2.7/2.8 | 7.0 | 600 | L | 202/198 |
TWINTEMP Electric Heat |
|
|
|
|
|
|
|
|
|
|
|
| ||
EQ08L11A |
| 7700 | 4000 | 115 | 6.5 | 733 | 11.2 | 1290 | 10.5 |
| 1.9 | 175 | Q | 80/76 |
ES12L33 |
| 12100/11900 | 10700/8900 | 230/208 | 4.8/5.0 | 1052/1017 | 16.0/14.7 | 3500/2900 | 11.5/11.7 |
| 2.9 | 320 | S | 115/111 |
ES16L33 |
| 16200/15900 | 10700/8900 | 230/208 | 7.4/8.0 | 1653/1656 | 16.0/14.7 | 3500/2900 | 9.8/9.6 |
| 4.7 | 360 | S | 120/116 |
EM18L34 |
| 17800/17600 | 13000/10600 | 230/208 | 8.1/8.8 | 1780/1760 | 19.5/17.0 | 4200/3500 | 10.0/10.0 |
| 4.4 | 400 | M | 164/160 |
EM24L34 |
| 23500/23000 | 13000/10600 | 230/208 | 11.2/12.1 | 2479/2421 | 19.5/17.0 | 4200/3500 | 9.5/9.5 |
| 7.0 | 400 | M | 160/154 |
EL36L35A |
| 36000/35700 | 17300/14300 | 230/208 | 18.0/19.6 | 4235/4200 | 24.0/22.4 | 5500/4650 | 8.5/8.5 |
| 11.0 | 725 | L | 224/220 |
*Sleeve dimensions listed on opposite page.
**Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 50° F to 115° F.
TwinTemp Heat Pump heating information (shown in red) indicates heat pump heating performance. TwinTemp Electric Heat heating information (shown in red) indicates electric heat strip performance. For TwinTemp Heat Pump electric heating performance refer to corresponding TwinTemp Electric Heat model.
Due to continuing research in new
As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® () models meet the ENERGY STAR® guidelines for energy efficiency.
The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.
7