Friedrich V(E, H)A09K25 Troubleshooting Chart - Cooling, Troubleshooting Chart - Heating

Models: V(E H)A09K25

1 44
Download 44 pages 40.78 Kb
Page 41
Image 41
TROUBLESHOOTING CHART — COOLING

TROUBLESHOOTING CHART — COOLING

REFRIGERANT SYSTEM DIAGNOSIS COOLING

Low Suction Pressure

High Suction Pressure

Low Head Pressure

High Head Pressure

Low Load Conditions

Low Air Flow Across

Indoor Coil

Refrigerant System

Restriction

Undercharged

High Load Conditions

High Air Flow Across

Indoor Coil

Reversing Valve not

Fully Seated

Overcharged

Low Load Conditions

Refrigerant System

Restriction

Reversing Valve not

Fully Seated

Undercharged

in System

High Load Conditions

Low Air Flow Across

Outdoor Coil

Overcharged

Non-Condensables (air)

Moisture in System

Defective Compressor

Defective Compressor

TROUBLESHOOTING CHART — HEATING

REFRIGERANT SYSTEM DIAGNOSIS HEATING

Low Suction Pressure

High Suction Pressure

Low Head Pressure

High Head Pressure

Low Air Flow Across

Outdoor Coil

Refrigerant System

Restriction

Outdoor Ambient Too High for Operation in Heating

Reversing Valve not

Fully Seated

Refrigerant System

Restriction

Reversing Valve not

Fully Seated

Outdoor Ambient Too High For Operation In Heating

Low Air Flow Across

Indoor Coil

Undercharged

Overcharged

Undercharged

Overcharged

Moisture in System

Defective Compressor

Defective Compressor

Non-Condensables (air)

in System

41

Page 41
Image 41
Friedrich V(E Troubleshooting Chart - Cooling, Troubleshooting Chart - Heating, Refrigerant System Diagnosis Cooling