Installation Instructions Model PXGA Standard Grille

1.Remove the center support and weatherboard if still installed in the sleeve.

2.Insert six plastic grommets into the grille openings from the outside of the grille as shown in Figure 9.

3.Insert two #8 x 3/8" sheet metal screws (provided) in the top two outside edge plastic grommets, and tighten them half way into the grommets.

4.CAUTION: Bodily injury can be caused by grilles falling from a building during installation. It is recommended that a safety line be attached to the grille and an anchor point inside the building during installation.

5.Grasp the grille by the attached plastic handles. Position it with the condensate drain knockouts facing down. From inside the building, maneuver the grille through the wall sleeve and pull toward you until the screw heads are inserted into the keyhole slots at the top of the wall sleeve. Tighten the two screws completely.

6.Insert the remaining screws into the remaining holes and tighten securely.

Figure 9

 

 

 

Standard Grille

 

 

 

 

 

Wall sleeve

 

 

 

Weatherboard

 

 

 

Center support

 

 

PXGA Standard Grille

 

 

Quantity

Description

 

 

1

Stamped Aluminum Grille

 

 

6

Plastic Grommets

Plastic handles

Plastic

6

#8 x 3/8" Sheet Metal Screws

grommets

 