ADJUSTING THE DIRECTION OF AIR CIRCULATION

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s AIR FLOW DIRECTION button. Hori- zontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.

Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.

Vertical Air Direction Adjustment

Press the AIR FLOW DIRECTION button (Fig. 6 Q).

Each time the button is pressed, the air direction range will change as follows:

Cooling/Dry

mode

1 Vertical Air Direction Adjustment 2 Press the AIR FLOW DIRECTION button (Fig. 6 Q). 3 Right-Left Adjustment (6) NOTE

Fan mode

1 En-11 2 Manual background 3 Manual background 4 Manual background 5 Manual background 6 Manual background 7

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry modes : Horizontal flow 1

During Fan mode

: Downward flow 6

If you wish to select a different airflow direction, you may use the remote control unit’s AIR FLOW DIRECTION button to choose a different setting.

During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this pe- riod.

NOTE

You can select the air direction 1, 2, 3, or 6 (downward) by pressing the AIR FLOW DIRECTION button.

Use the air direction 6 when you want to cool yourself for a while after taking a bath or shower, or after coming back home in summer months.

But, for prevention of condensation on the louver, the air direction 6 is auto- matically released after 30 minutes and turned to the air direction 3.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air flow in the direction you prefer.

Right-Left Louvers

Manual background CAUTION!

Never place fingers or foreign objects inside the outlet ports, since the internal fan oper- ates at high speed and could cause personal injury.

Always use the remote control unit’s AIR FLOW DIRECTION button to adjust the vertical airflow louvers. Attempt- ing to move them manually could re- sult in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Always operate the Air Flow Direction Louvers and the Power Diffuser with the air flow direction buttons on the remote control. Forcible movement by hand can cause incorrect operation. In such a case, stop the operation to let the unit return to normal condition.