WARNING

ELECTRIC SHOCK HAZARD

Turn off electric power before service or installation.

Extreme care must be used, if it becomes necessary to work on equipment with power applied.

Failure to do so could result in serious injury or death.

WARNING

HIGH PRESSURE HAZARD

Sealed Refrigeration System contains refrigerant and oil under high pressure.

Proper safety procedures must be followed, and proper protective clothing must be worn when working with refrigerants.

Failure to follow these procedures could result in serious injury or death.

Undercharged Refrigerant Systems

 

A check of the amperage drawn by the compressor

An undercharged system will result in poor performance

motor should show a lower reading. (Check the Unit

(low pressures, etc.) in both the heating and cooling cycle.

Specification.) After the unit has run 10 to 15 minutes,

Whenever you service a unit with an undercharge

of

check the gauge pressures. Gauges connected to system

with an undercharge will have low head pressures and

refrigerant, always suspect a leak. The leak must

be

substantially low suction pressures.

repaired before charging the unit.

 

 

 

To check for an undercharged system, turn the unit on, allow the compressor to run long enough to establish working pressures in the system (15 to 20 minutes).

During the cooling cycle you can listen carefully at the exit of the metering device into the evaporator; an intermittent hissing and gurgling sound indicates a low refrigerant charge. Intermittent frosting and thawing of the evaporator is another indication of a low charge, however, frosting and thawing can also be caused by insufficient air over the evaporator.

Checks for an undercharged system can be made at the compressor. If the compressor seems quieter than normal, it is an indication of a low refrigerant charge.

Overcharged Refrigerant Systems

of the evaporator will not be encountered because the

Compressor amps will be near normal or higher.

refrigerant will boil later if at all. Gauges connected to

system will usually have higher head pressure (depending

Noncondensables can also cause these symptoms.

upon amount of over charge). Suction pressure should be

To confirm, remove some of the charge, if conditions

slightly higher.

improve, system may be overcharged. If conditions don’t

 

 

 

improve, Noncondensables are indicated.

 

 

 

Whenever an overcharged system is indicated, always

 

 

 

make sure that the problem is not caused by air flow

 

 

 

problems. Improper air flow over the evaporator coil may

 

 

 

indicate some of the same symptoms as an over charged

 

 

 

system.

 

 

 

An overcharge can cause the compressor to fail, since it

 

 

 

would be “slugged” with liquid refrigerant.

 

 

 

The charge for any system is critical. When the compressor

 

 

 

is noisy, suspect an overcharge, when you are sure that

 

 

 

the air quantity over the evaporator coil is correct. Icing

 

 

 

 

 

 

 

39

Page 40
Image 40
Friedrich SS14N10*, SS12N10*, SS15N30*, SS10N10*, SM18N30* Undercharged Refrigerant Systems, Overcharged Refrigerant Systems

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.