Friedrich SS10N10*, SS14N10*, SS12N10*, SS15N30* Replace fuse, reset breaker. If repeats, check

Models: SM18N30* SS10N10* SS15N30* SS12N10* SS14N10*

1 95
Download 95 pages 23 Kb
Page 63
Image 63

COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS

Problem

Possible Cause

Possible Solution

 

 

Replace fuse, reset breaker. If repeats, check

 

Fuse blown or circuit tripped

fuse or breaker size. Check for shorts in unit

 

 

wiring & components

 

Power cord not plugged in

Plug it in

Unit does not run

System button in “OFF” position

Set correctly

Inoperative system button or open

Test for continuity. Check alarms. Correct

 

 

electronic control board

as needed.

 

Loose or disconnected wiring

Check wiring & connections. Reconnect per

 

control board or other components

wiring diagram

 

 

 

Problem

Possible Cause

Possible Solution

 

Dirty filter

Clean as recommended in Owner’s Manual

 

 

Check for dirty or obstructed coil. Use

 

Restricted airflow

pressure wash or biodegradable cleaning

 

 

agent to clean

Evaporator coil

Inoperative thermistor

Check alarms. Replace as necessary.

freezes up

Short of refrigerant

De-ice coil & check for leak

 

Inoperative fan motor

Test fan motor & replace if inoperative

 

Partially restricted capillary tube

De-ice coil. Replace capillary tube.

 

 

 

Problem

Possible Cause

Possible Solution

 

Excessive heat load

Unit undersized. Test cooling performance &

 

replace with larger unit if needed. See sizing chart.

 

 

 

Restriction in line

Check for partially iced coil & check

Compressor runs

temperature split across coil

 

continually & does

Refrigerant leak

Find leak and repair.

not cycle off

 

 

Compressor relay contacts stuck

Check operation of t-stat. Replace if contacts

 

 

remain closed.

 

 

 

Remote wall T-stat incorrectly wired

Refer to appropriate wiring diagram

 

 

 

 

Thermistor shorted

Replace thermistor or electronic control board

 

 

 

Problem

Possible Cause

Possible Solution

 

Compressor relay contacts stuck

Replace electronic control board

 

 

 

Electronic control

Temperature set at coldest point

Turn to higher temp. setting to see if unit

cycles off. If not, replace control board.

board does not

 

turn unit off

 

 

Incorrect wiring

Refer to appropriate wiring diagrams

 

 

 

 

 

Unit undersized for area to be

Refer to industry standard sizing chart

 

cooled

 

 

 

Defective thermistor

Replace thermistor or electronic control board

 

 

 

62

Page 63
Image 63
Friedrich SS10N10*, SS14N10*, SS12N10*, SS15N30*, SM18N30* service manual Replace fuse, reset breaker. If repeats, check

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.