Installation Information / Sleeve Dimensions

 

 

Depth

Shell Depth to

Minimum

Minimum

 

 

with Front

Louvers

Extension

Extension

Sleeve

 

 

 

Height

Width

 

Into Room*

Outside*

Window Width

Minimum** Maximum

Thru-the-wall Installation

Finished Hole

Height

Width

Max. Depth

S

15 15/16"

25 15/16"

29"

8 ¾"

5 ¾”

16 15/16

27 3/8"

42"

16 3/16”

26 3/16”

7 3/8"

M

17 15/16"

25 15/16"

29"

8 ¾"

5 ¾

16 15/16

27 3/8"

42"

18 3/16”

26 3/16”

7 3/8

L

20 3/16"

28"

35 ½”

16 ½"

5 3/8

18 15/16

29 7/8

42"

20 3/8"

28 ¼"

15 1/8

*Minimum extensions when mounted in a window.

**Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation. NOTE: S,M and L sleeves may be installed in window with no side kits if properly installed.

Circuit Rating/ Breaker

 

Circuit Rating

Plug

Power Cord

Wall Outlet

Model

Breaker or

Face

T-D Fuse

(NEMA#)

Length (ft.)

Appearance

SS08N10, SS10N10, SS12N10 and

125V - 15A

5 - 15P

6

 

 

 

 

 

 

 

SS14N10, SM15N10, YS10N10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS12N30, SS15N30, SM18N30 and

250V - 15A

6 - 15P

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM21N30, SL22N30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM24N30, SL24N30,SL28N30,

250V - 20A

6 - 20P

4

 

 

 

 

 

 

 

ES12N33, ES15N33, YS12N33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SL36N30, EM18N34, EM24N34,

250V - 30A

6 - 30P

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EL36N35, YM18N34 and YL24N35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front

(C)

(B)SIDE VIEW

For the best cooling performance and highest energy efficiency

Keep the filter clean

Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly.

Provide good air flow

Make sure the airflow to and from the unit is clear. Your air conditioner puts the conditioned air out at the top of the unit, and takes in unconditioned air at the bottom. Airflow is critical to good operation. It is just as important on the outside of the building that the airflow around the unit exterior is not blocked.

Unit placement

If your air conditioner can be placed in a window or wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit’s efficiency.

Insulation

Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows.

Proper installation of seal gasket

Make sure the seal gasket has been installed properly to minimize noise and improve efficiency. If the seal gasket has not been installed, please refer to the installation instructions.