FAN
MODE

Control Panel Operation Instructions

SYSTEM - The SYSTEM button allows you to sequentially select the modes of operation. To select, press once and let go.

AUTO MODE

Automatically changes between HEAT and COOL

 

(HEAT and COOL ONLY Units)

COOL MODE

HEAT MODE

Not available on some models

FAN ONLY MODE

 

 

AUTO MODE COOL

 

 

- AUTO -

F

 

 

 

AUTO FAN

 

 

SET POINT

 

 

COOL ONLY MODE

FRR204

 

 

 

 

F

 

AUTO FAN

 

 

SET POINT

 

 

HEAT MODE

FRR103

 

 

 

 

F

 

AUTO FAN

 

 

SET POINT

 

 

FAN ONLY MODE

FRR104

 

 

FRR105

When in the SYSTEM COOL or HEAT or FAN ONLY mode, you

can also select FAN MODE, FAN SPEED, TIMER SCHEDULE, and

. The SYSTEM MODE does not change.

FAN MODE – The button allows you to select between AUTO FAN and CONTINUOUS modes. To select, press once and let go.

F

AUTO FAN

SET POINT

FRR112

When in the AUTO FAN mode, the fan operates only when the system has a demand to cool or heat the room. Note: the fan is off (no fan speed icon), indicating no command for cooling or heating.

AUTO FAN (Cooling Demand)

F

AUTO FAN

SET POINT

FRR106

System has a demand for cooling. The fan is operating at a medium speed.

CONTINUOUS

F

CONTINUOUS

SET POINT

FRR113

In the CONTINUOUS fan mode, the fan operates all the time. The system periodically cools or heats the fan's airflow but the flow of air does not stop.

FAN SPEED - Cooling only units have 4 fan speeds, except models SL28 and SL36. All Cool+Heat units only have 3 fans speeds.

FAN SPEED - The FAN button allows you to toggle between four speeds: LOW, MEDIUM, HIGH, MAX and AUTO speed operation. Press once and let go each time.

SPEED

4 Speed

AUTO

FRR095

During the (SYSTEM mode COOL or HEAT), the fan speed automatically varies depending on the difference between the unit's set point on the control panel and the actual room temperature. Let me explain. Say for example, you’re working in your garage and you open the big door for several minutes. The system will sense a wide difference between the set point and the actual room temperature. When this occurs, the system fan speed increases to HIGH for a period of time. The fan speed decreases, in step, as the temperature difference decreases. When the room temperature matches the system's set point, fan speed returns to the lowest setting, and if the fan mode is on AUTO FAN, the fan will stop.

13

Page 14
Image 14
Friedrich SM18N30*, SS14N10*, SS12N10*, SS15N30*, SS10N10* service manual Control Panel Operation Instructions

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.