THERMISTORS’ RESISTANCE VALUES (This Table Applies to All Thermistors)

TEMP

RESISTENCE (K Ohms)

RESISTANCE

 

 

 

 

TOLERANCE %

F

MIN

CENTR

MAX

MIN

MAX

-25

210.889

225.548

240.224

6.50

6.51

-20

178.952

190.889

202.825

6.25

6.25

-15

151.591

161.325

171.059

6.03

6.03

-10

128.434

136.363

144.292

5.81

5.81

-5

108.886

115.340

121.794

5.60

5.60

0

92.411

97.662

102.912

5.38

5.38

5

78.541

82.812

87.083

5.16

5.16

10

66.866

70.339

73.812

4.94

4.94

15

57.039

59.864

62.688

4.72

4.72

20

48.763

51.060

53.357

4.50

4.50

25

41.786

43.654

45.523

4.28

4.28

30

35.896

37.415

38.934

4.06

4.06

31

34.832

36.290

37.747

4.02

4.02

32

33.803

35.202

36.601

3.97

3.97

33

32.808

34.150

35.492

3.93

3.93

34

31.846

33.133

34.421

3.89

3.89

35

30.916

32.151

33.386

3.84

3.84

36

30.016

31.200

32.385

3.80

3.80

37

29.144

30.281

31.418

3.75

3.75

38

28.319

29.425

30.534

3.76

3.77

39

27.486

28.532

29.579

3.67

3.67

40

26.697

27.701

28.704

3.62

3.62

45

23.116

23.931

24.745

3.40

3.40

50

20.071

20.731

21.391

3.18

3.18

55

17.474

18.008

18.542

2.96

2.96

60

15.253

15.684

16.115

2.75

2.75

65

13.351

13.697

14.043

2.53

2.53

66

13.004

13.335

13.666

2.48

2.48

67

12.668

12.984

13.301

2.44

2.44

68

12.341

12.644

12.947

2.39

2.39

69

12.024

12.313

12.603

2.35

2.35

70

11.716

11.993

12.269

2.31

2.31

71

11.418

11.682

11.946

2.26

2.26

72

11.128

11.380

11.633

2.22

2.22

73

10.846

11.088

11.329

2.18

2.18

74

10.574

10.804

11.034

2.13

2.13

75

10.308

10.528

10.748

2.09

2.09

76

10.051

10.260

10.469

2.04

2.04

77

9.800

10.000

10.200

2.00

2.00

78

9.550

9.748

9.945

2.03

2.03

79

9.306

9.503

9.699

2.07

2.07

80

9.070

9.265

9.459

2.10

2.10

81

8.841

9.033

9.226

2.13

2.13

82

8.618

8.809

9.000

2.17

2.17

83

8.402

8.591

8.780

2.20

2.20

84

8.192

8.379

8.566

2.23

2.23

85

7.987

8.172

8.358

2.27

2.27

86

7.789

7.972

8.155

2.30

2.30

87

7.596

7.778

7.959

2.33

2.33

88

7.409

7.589

7.768

2.37

2.37

89

7.227

7.405

7.583

2.40

2.40

90

7.050

7.226

7.402

2.43

2.43

91

6.878

7.052

7.226

2.47

2.47

92

6.711

6.883

7.055

2.50

2.50

93

6.548

6.718

6.889

2.53

2.53

94

6.390

6.558

6.727

2.57

2.57

95

6.237

6.403

6.569

2.60

2.60

96

6.087

6.252

6.417

2.63

2.63

97

5.942

6.105

6.268

2.67

2.67

98

5.800

5.961

6.122

2.70

2.70

99

5.663

5.822

5.981

2.73

2.73

100

5.529

5.686

5.844

2.77

2.77

105

4.912

5.060

5.208

2.93

2.93

110

4.371

4.511

4.651

3.10

3.10

115

3.898

4.030

4.161

3.27

3.27

120

3.482

3.606

3.730

3.43

3.43

57

Page 58
Image 58
Friedrich SS10N10*, SS14N10*, SS12N10*, SS15N30*, SM18N30* service manual Temp

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.