Friedrich ZQ08B10, ZQ10B10, CP10A10 Refrigerating Cycle, Motor, 2.4.1CONDENSER CAUTION, Evaporator

Models: CP12A10 CP08A10 CP10A10 ZQ10B10 ZQ08B10

1 28
Download 28 pages 43.89 Kb
Page 10
Image 10
2.3.5 MOTOR

2.3.5 MOTOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the turbo fan. (Refer to section 2.2.1)

3.Remove the fan. (Refer to section 2.2.2)

4.Remove the 4 screws which fasten the motor to the air guide. (See Figure 13)

5.Remove the motor.

6.Re-install the components by referring to the removal procedure, above.(See Figure 13)

2.4 REFRIGERATING CYCLE

2.4.1CONDENSER CAUTION

Discharge the refrigerant system using a FreonTM Recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Remove the valve when finished.

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the 5 screws which fasten the brace.(Refer to section 2.2.1)

3.Remove the 5 screws which fasten the condenser and shroud.

4.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

5.Remove the condenser.

6.Re-install the components by referring to notes. (See Figure 14)

2.4.2 EVAPORATOR

1.Remove the control box.(Refer to section 2.1.3)

2.Remove the air guide upper. (Refer to section 2.2.1)

3.Remove the 2 screws which fasten the evaporator.

4.Move the evaporator sideways carefully. (Refer to section 2.2.1)

5.After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.

6.Remove the evaporator.

7.Re-install the components by referring to notes. (See Figure 15)

Figure 13

Figure 14

Figure 15

Ñ10Ñ

Page 10
Image 10
Friedrich ZQ08B10, ZQ10B10, CP10A10 Refrigerating Cycle, Motor, 2.4.1CONDENSER CAUTION, Evaporator, Figure Figure Figure