Friedrich ZQ08B10, ZQ10B10 Troubleshooting Guide, Unit runs but poor cooling Ineffective Cooling

Models: CP12A10 CP08A10 CP10A10 ZQ10B10 ZQ08B10

1 28
Download 28 pages 43.89 Kb
Page 15
Image 15
3.3 TROUBLESHOOTING GUIDE

3.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged air filter.

Obstruction at air outlet

Correct above problem.

Check clogging in refrigera- tion circuit.

Repair clogging in refrigera- tion circuit.

Check outdoor coil

(heat exchanger) & the fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 18~26°F.

Check heat load increase.

Clean condenser.

Not on separate circuit.

Check inside gas pressure.

Adjusting of refrigerant charged.

Malfunction of compressor.

Replacement of compressor.

Ñ15Ñ

Page 15
Image 15