Installation Instructions

Installation Instructions

Installation and service must be performed by a qualified technician.

IMPORTANT: Save for the local electrical inspector’s use. Read and save these instructions for future reference.

Clearances and Dimensions

a.Provide adequate clearances between the range and adjacent combustible surface (1.3cm (1/2”) to the cabinet side walls and the rear wall).

b.Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.

c.Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level.

FRONT

 

 

 

SIDE

VIEW

 

 

 

VIEW

 

76.2 cm (30”) C

 

 

 

Minimum

*

 

 

 

 

 

Minimum to

33 cm

Minimum to

1.3 cm

 

(13”)

45.7 cm cabinets on

Maximum depth for

wall on either

(1/2”)

(18”)

either side of

cabinets above

side of range.

 

 

 

 

range.

range top.

 

 

 

91.4 cm

 

 

 

 

(36”)

 

 

 

 

B

 

DIMENSIONS

 

A

B

C

76.2 cm (30”) 78.7 cm (31”) 76.2 cm (30”)

A

66 cm (26”)

122 cm (48”)

Maximum

91.4 ± 0.3 cm

(36 ± 1/8”)

114.3cm (45”)

Door Open

*76.2 cm (30”) Minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 61 cm (24”) Minimum when bottom of wood or metal cabinet is protected by not less than 0.64 cm (1/4”) flame retardant millboard covered with not less than 0.038 cm (0.015”) stainless steel, 0.061 cm (0.024”) aluminum or 0.051 cm (0.020”) copper. 1.3 cm (1/2”) clearance is the minimum for the rear and sides of the range. Follow all dimension requirements provided above to prevent property damage, Potential fire hazard, and incorrect countertop and cabinet cuts.

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 12.7 cm (5”) beyond the bottom of the cabinets.

Electrical Connection Requirements

Plug the range cable (4 conductors) into a 4 conductor range outlet. Outlet must be properly grounded and in accordance with the Canadian Electrical Code (CSA Stan- dard (C22.1 Part 1 -- latest edition) -- and any local electrical code requirements.

Location

Set your new range 1.3 cm (1/2”) away from the rear wall and line it up with the kitchen counters. Make sure there is at least 1.3 cm (1/2”) of clearance between each side of the range and the kitchen counters. Allow 7.6 cm (3”) min. clearance between your range and the refrigerator, if they are side by side.

Circuit Protection (Models with electric oulet(s))

As a protection against surcharge, a 15 amp, 120 volt breaker is provided for each of the electric outlet(s) (2 max.) located on top or underneath of the control panel. Models with no electric outlet have no breaker.