Cabinet Service Procedures

2.3 Accessing the Electronic Components

1.The component shelf is accessed by removing two screws on each side of the unit (Fig. 1).

2.Lift and remove the sides, which exposes screws that hold the top in place (Fig. 2).

3.The components are annotated below (Fig. 3).

LON board

Cooling fans

LON filter

Fans:NOTE:areThespecificcoolingtofans regionsrest onofducts,the cabinetand cool

and ducted to direct specific regions of the

the air flow. cabinet.

Master

Display

Board

Master Control Board

LON filter

Power supply

Figure 3

Relay

All the components are readily removed. There are no replaceable components on the circuit boards.

2.4 Circuit Board LED Diagnostics

Master Control Board:

HB LED is a heartbeat; should be flashing when in the normal

in- use mode. Flash rate is not

Fig. 4: Master Control Board LED's

critical.

 

ACT LED similar to HB but flashes at a faster rate.

OK LED toggles each time a valid communication packet is sent and received. Normally a very fast flicker.

2-6

Page 11
Image 11
Frymaster 8196606 manual Accessing the Electronic Components, Circuit Board LED Diagnostics