Cabinet Troubleshooting

Failure modes not accompanied by a master control display are shown below with possible causes and tests.

 

Symptom

 

 

 

Possible Causes

 

 

Tests

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• No power to cord.

 

• Check for line voltage at the switch

 

Unit fails to power

 

•

Blown 20 amp fuse.

 

and the transformer.

 

up; fans don’t run.

 

•

Circuit breaker open.

 

• Reset circuit breaker.

 

 

 

 

 

 

 

 

Unit powers up and

 

•

Broken or improperly

 

• Switch ribbon cable from functioning

 

fans run; a display

 

 

seated ribbon cable.

 

display to failed component to isolate

 

fails to light.

 

•

Defective display.

 

problem.

 

 

 

 

 

 

 

 

 

 

Unit powers up and

 

•

 

 

 

• Check for 5VDC at communication

 

fans run; all

 

Failed power supply.

 

 

 

 

board and distribution boards.

 

displays fail to light.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Ensure heater leads and power inputs

 

 

 

 

 

 

 

 

on the distribution boards are properly

 

 

 

 

 

 

 

 

seated.

 

 

 

 

 

 

 

 

• Test for 208VAC input on distribution

 

 

 

 

•

Improper wiring on

 

board and 208VAC output from heater

 

 

 

 

 

leads to heater plate when the unit is

 

Rows heat

 

 

distribution board.

 

calling for heat.

 

 

•

Defective distribution

 

• Switch power leads from properly

 

improperly or not at

 

 

board.

 

operating row to faulty row to isolate

 

all.

 

 

 

 

 

•

Defective heater.

 

problem.

 

 

 

 

 

 

 

 

 

•

Defective sensor.

 

• Check resistance of RTD lead against

 

 

 

 

 

 

 

 

temperature chart. See Page 2-4.

 

 

 

 

 

 

 

 

• Switch RTD lead from properly

 

 

 

 

 

 

 

 

operating row to faulty row to isolate

 

 

 

 

 

 

 

 

problem.

 

 

 

 

 

 

 

 

• Test continuity of heater plate.

 

 

 

 

 

 

 

 

 

 

3-2

Page 18
Image 18
Frymaster 8196606 manual Symptom Possible Causes Tests