Frymaster BK1814 Series Gas Fryers
Chapter 3: Installation
to the first two threads. Doing so may allow some of the compound to enter the gas stream, resulting in clogging of burner orifices and/or the control valve.
2.Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks with a leak detection fluid.
3.Close the fryer drain valve and fill the frypot with water and
DANGER
4.The burner manifold pressure should be checked at this time by the local gas company or an authorized service agent. The tables below and on the following page list the burner manifold gas pressures for the various gas types that can be used with this equipment.
5.Check the programmed temperature or
3.6Converting to Another Gas Type
DANGER
This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific
Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.7 of this manual.
CE Gas Conversion Kits