Frymaster BK1814 Series Gas Fryers

Chapter 3: Installation

The 1814 Series gas fryer has received the CE mark for the countries and gas categories indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU and category 3P/B, which is 23kW.

CE Approved Gas Categories by Country

 

 

COUNTRIES

CATEGORIES

GAS

PRESSURE (MBAR)

 

 

 

 

AUSTRIA (AT)

II2H3B/P

G20

20

 

 

 

 

G30, G31

50

 

 

 

 

 

 

 

 

 

 

BELGIUM (BE)

I2E(R)B

G20, G25

20, 25

 

 

 

 

I3+

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

DENMARK (DK)

II2H3B/P

G20

20

 

 

 

 

G30, G31

30

 

 

 

 

 

 

 

 

 

 

 

II2Esi3+

G20, G25

20, 25

 

 

 

 

FRANCE (FR)

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

II2Esi3P

G20, G25

20, 25

 

 

 

 

 

 

 

 

 

 

G31

50

 

 

 

 

 

 

 

 

 

 

FINLAND (FI)

II2H3B/P

G20

20

 

 

 

 

G30, G31

30

 

 

 

 

 

 

 

 

 

 

 

II2ELL3B/P

G20, G25

20

 

 

 

 

GERMANY (DE)

G30, G31

50

 

 

 

 

 

 

 

 

 

 

I3P

G31

50

 

 

 

 

GREECE (GR)

II2H3+

G20

20

 

 

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

ITALY (IT)

II2H3+

G20

20

 

 

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

IRELAND (IE)

II2H3+

G20

20

 

 

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

LUXEMBOURG (LU)

II2E3B/P

G20

20

 

 

 

 

G30, G31

50

 

 

 

 

 

 

 

 

 

 

 

II2L3P

G25

25

 

 

 

 

NETHERLANDS (NL)

G31

50

 

 

 

 

 

 

 

 

 

II2L3B/P

G25

25

 

 

 

 

 

 

 

 

 

 

G30, G31

30

 

 

 

 

 

 

 

 

 

 

NORWAY (NO)

I3B/P

G30, G31

30

 

 

 

 

PORTUGAL (PT)

II2H3+

G20

20

 

 

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

 

II2H3+

G20

20

 

 

 

 

SPAIN (ES)

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

II2H3P

G20

20

 

 

 

 

 

 

 

 

 

 

G31

37, 50

 

 

 

 

 

 

 

 

 

 

SWEDEN (SE)

II2H3B/P

G20

20

 

 

 

 

G30, G31

30

 

 

 

 

 

 

 

 

 

 

UNITED KINGDOM (UK)

II2H3+

G20

20

 

 

 

 

G30, G31

28-30, 37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE Standard

Required airflow for the combustion air supply is 2m3/h per kW.

1.Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the fryer and to the building gas line.

NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units are connected to the gas supply line at the rear of the unit.

When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound

3-6

Page 20
Image 20
Frymaster BK1814 operation manual CE Standard, Required airflow for the combustion air supply is 2m3/h per kW