Frymaster FMCF mode. cont, CM III.5 displays, as it comes out of, melt cycle, Heating mode

Models: FMCF

1 50
Download 50 pages 20.61 Kb
Page 43
Image 43
mode. (cont.)

CF SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6.2Troubleshooting Fryers with Solid State (Analog), Digital, or CM III.5 Controllers (cont.)

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

 

B. If available, substitute controller

CM III.5 will not go

 

known to be good for suspect

 

controller (see Section 6.6). If

into programming

B. Failed controller.

fryer operates normally, order

mode. (cont.)

 

 

replacement controller from

 

 

 

 

FASC.

 

A. Setpoint incorrect.

A. Verify that setpoint has been

CM III.5 displays

properly entered.

 

 

B. Disconnect unit from electrical

as it comes out of

 

B. Temporary controller malfunction

power, wait at least one minute,

melt cycle

caused by voltage surge.

and reconnect unit to the power

 

OR

 

supply.

 

C. If available, substitute controller

 

 

Heating mode

 

known to be good for suspect

 

controller (see Section 6.6). If

indicator does not

C. Failed controller.

fryer operates normally, order

come on at all.

 

 

replacement controller from

 

 

 

 

FASC.

 

 

A. Refer to Burner does not light

 

A. Burner is not lit.

problem on the following page in

Heating mode

 

Sec. 6.3.

 

B. If available, substitute controller

indicator is on but

 

 

known to be good for suspect

fryer is not heating

 

 

controller (see Section 6.6). If

properly.

B. Failed controller.

fryer operates normally, order

 

 

 

 

replacement controller from

 

 

FASC.

6-3