Frymaster FMCF or the transfer is very, slow. cont, Power Shower is not, spraying properly

Models: FMCF

1 50
Download 50 pages 20.61 Kb
Page 46
Image 46
or the transfer is very

CF SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6.4 Troubleshooting the Built-In Filtration System (cont.)

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

B. Improperly installed or prepared

 

 

filter pan components.

B. Remove the oil from the filter pan

 

 

 

Test: Close the drain valve.

and replace the filter paper,

 

ensuring that the filter paper

 

Move the filter handle to the OFF

 

support screen is in place under

 

position, pull the filter pan (and

 

the paper.

 

Power Shower, if so equipped)

 

 

 

from the unit. Move the filter

If this does not correct the

 

handle to the ON position.

 

problem, the filter tube suction

 

 

Pump starts, but no

If a strong stream of air is being

tube is probably blocked. Remove

the blockage using a thin, flexible

transfer takes place

pumped out of the oil return port

wire. If unable to remove the

or the transfer is very

(or the Power Shower port), the

blockage, call FASC.

slow. (cont.)

problem is with the filter pan

 

 

components.

 

 

 

C. Verify that filter connection

 

 

O-rings are present and in good

 

C. Improperly installed or prepared

condition.

 

 

 

filter pan components.

Replace the filter paper, ensuring

 

 

that the filter paper support screen

 

 

is properly positioned under the

 

 

paper.

 

 

 

 

A. Plugged openings or solidified

 

 

shortening in the Power Shower.

A. Clean the Power Shower per

 

 

 

Test: Look for oil squirting out

instructions in Chapter 5 of this

 

manual.

 

around the Power Shower gasket.

 

 

Power Shower is not

If so, Power Shower is obstructed.

 

B. Missing/worn O-rings and gasket

B. Verify that O-rings and gasket are

spraying properly.

on Power Shower.

present and in good condition.

 

C. Missing paper in filter pan. (This

 

 

causes too much pressure in the

 

 

oil return lines, resulting in a

C. Verify that filter paper is properly

 

strong flow through the Power

installed in the filter pan.

 

Shower, but also squirting of oil

 

 

from around the gasket.)

 

6-6

Page 46
Image 46
Frymaster FMCF or the transfer is very, slow. cont, Power Shower is not, spraying properly, Pump starts, but no