Frymaster FMCF Troubleshooting Abnormal Burner Operation, Flame is visible, above flue opening

Models: FMCF

1 50
Download 50 pages 20.61 Kb
Page 47
Image 47
6.5 Troubleshooting Abnormal Burner Operation

CF SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6.5 Troubleshooting Abnormal Burner Operation

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

A. Burner gas pressure is too high.

A. Call FASC to adjust pressure to

Flame is visible

B. Gas valve vent tube clogged.

recommended standard.

 

above flue opening

B. Remove and clean vent tube and

and burner is

 

C. Gas valve regulator defective.

reinstall.

excessively noisy.

 

 

C. Call FASC to replace gas valve.

Fryer is operating

 

Shut the fryer down and clean the gas

normally, but flames

Obstructed gas valve vent tube.

valve vent tube in accordance the

are rolling out of the

instructions on Page 5-5 of this

front of the burner.

 

manual.

6-7

Page 47
Image 47