![](/images/new-backgrounds/1072207/7220731x1.webp)
1.6.5 Replacing an Ignitor Assembly
DANGER
Drain the frypot or remove the handle from the drain valve before proceeding further.
1.Disconnect the fryer from the electrical supply.
2.Disconnect the flame sensor wire by carefully pulling its
Flame Sensor Wire
Gas Enrichment Tube
Ignition Cable
3.Remove the sheet metal screws securing the ignitor to the mounting plate and pull the ignitor from the fryer.
4.Reverse the procedure to install the replacement ignitor.
1.6.6 Replacing or Cleaning a Combustion Air Blower
1.Disconnect the blower wiring harness, remove the blower assembly mounting nuts, and remove the blower assembly from the fryer. If cleaning the motor, continue with Step 2; otherwise, install the replacement blower, reconnect the wiring harness, and then go to Step 6.
Wiring connection | Blower assembly |
| mounting nuts |