6.Light the fryer in accordance with the procedure described in Chapter 3, Section 3.2 of the Pro
7.After the burners have been lit for at least 90 seconds, observe the flames through the burner sight glasses located on each side of the combustion air blower.
Left Viewing | Right |
Port is behind | Viewing |
motor. | Port. |
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page
Adjusting the Air/Gas Mixture
On the side of the blower housing opposite the motor is a shutter plate with a locking nut. Loosen the nut enough to allow the shutter to be moved, then adjust the position of the shutter to open or close the air intake opening until a bright
Loosen this nut and rotate shutter to open or close air intake.