8. Operator Troubleshooting Guide

Symptom

Possible Cause

 

 

 

No power

No computer display; no flow from

Circuit breaker out

Low voltage

air tower

Bad fuse

 

Bad transformer

 

Hi-limit out

No flow from air tower

Bad latching relay

 

 

 

RTD probe has failed. Isolate failed

 

component by checking temperature of

 

air and heater plate with the temperature

After 20 minutes of operation

display keys on the computer. The plate

computer display shows PROB

temperature should be within ± 15°F of

 

setpoint. The air heat should be within ±

 

25°F of setpoint. If both temperatures are

 

good, the computer is likely bad.

After 20 minutes of operation

Plate heater, plate heater relay or RTD

computer display shows HI

are faulty.

After 20 minutes of operation

Air heater, air heater relay or RTD are

computer display shows LO

faulty

 

 