8. Operator Troubleshooting Guide
Symptom | Possible Cause |
|
|
| No power |
No computer display; no flow from | Circuit breaker out |
Low voltage | |
air tower | Bad fuse |
| Bad transformer |
| |
No flow from air tower | Bad latching relay |
|
|
| RTD probe has failed. Isolate failed |
| component by checking temperature of |
| air and heater plate with the temperature |
After 20 minutes of operation | display keys on the computer. The plate |
computer display shows PROB | temperature should be within ± 15°F of |
| setpoint. The air heat should be within ± |
| 25°F of setpoint. If both temperatures are |
| good, the computer is likely bad. |
After 20 minutes of operation | Plate heater, plate heater relay or RTD |
computer display shows HI | are faulty. |
After 20 minutes of operation | Air heater, air heater relay or RTD are |
computer display shows LO | faulty |
|
|